5
3) AUTOMATIC DOOR OPERATION
WARNING!!
Always contact the assistance technician before commissioning the door, to learn how the automation works.
Switch on the power supply by means of the system switch.
The automation electronic control unit beeps shortly to indicate that the automatic door is powered.
The first opening command starts a calibration cycle during which the door opening speed is very low until the end of the stroke, to find the
stop point; after the delay time has elapsed, the door closes back at normal speed.
3.1) NORMAL DOOR OPERATION
When something enters the motions sensor (internal and/or external radar) detection area the door opens and stays open until sensors
detect the presence, then once the pause delay has elapsed the door closes back.
When the manual door opening button is pressed the door opens and stays open until the command remains active, t h e n o n c e t h e
pause delay has elapsed it closes back.
If the closing safety sensor detects a presence,the door immediately reopens, and stays open as long as the sensor remains engaged.
If the opening safety sensor detects a presence, the door slows down and proceeds very slowly until the opening stroke is
completed.
If during the opening motion the door bumps against an obstacle, it stops and closes back.
When it opens again, later, it slows down near the point where it had met the obstacle, to avoid further impact.
If during the closing motion the door bumps against an obstacle, it stops and opens back.
When it closes again, later, it slows down near the point where it had met the obstacle, to avoid further impact.
3.2) DOOR OPERATION IN NIGHT LOCK MODE
The door cannot be opened through the external and internal radars.
The door can only be opened by pressing the OPEN button, or using the Spyco radio-control, if any.
The safety function (sensors and behaviour in case of obstruction) are active and work as described in par. 3.1. for normal operation.
4) PROGRAM SELECTORS
The program selector allows the door user to select the operating mode.
Depending on one's preferences, the EV-MSEL mechanical key selector or the N-DSEL digital programmer can be used.
Each program selector is described in details below.
4.1) EV-MSEL MECHANICAL KEY SELECTOR
The key can be taken out of the selector when in any position in order to prevent the work program from undesired changes.
Open door program
The door stops in complete opening position.
Reduced opening during winter
For reducing the opening space
Bi-directional automatic program
The door automatically opens when each opening control activates.
Single-direction automatic program output only
To exclude the incoming detection on external radar input
Night lock program
The door can only be opened through the OPEN input or using the SPYCO remote control, if any.
OPERATING MODE
Insert and rotate the key in EV-MSEL selector to select the program desired.