FUNCTION STATE
EXPLANATION
F44
Not used
F45m
Multiple
selection
function
Multiple selection function that allows to set the mode of operation of the output on connector OUT2 for the relay module "UR24E"
A
The output displays the state of the input LOCK1 of the control unit ET‑LOGIC‑B. Output active with closed contact, inactive with open contact. This function can
be used to indicate the state of the electric lock and the position of the leaf when you install the electric lock with microswitch.
B
Door crossing warning gong. The GONG function is an entry warning triggered by the activation of the closure safety sensor while the automatic door is being
crossed. Please refer to the "Gong function" paragraph.
C
Air curtain (device generating a flow of cold or heated air to separate the outside temperature from the inside temperature).
The output turns on when the door is moving, whereas it turns off when the door is closed.
D
Battery state. The activation of the output reports the status of damaged battery.
E*
Door state display. Slow flash during opening, permanently lit with the door open, fast flashing during closure, off with door closed.
F
Alarm warning.
The output activates for 2 seconds if with door closed in Night Lock an opening radar or a safety closing sensor activate.
G
Maintenance signal.
The output activates when the door reaches the number of cycles provided for by the maintenance plan set by the potentiometer P48.
H
The output signals the activation of the STOP input or of the photocell PRJ38 operating as motor stop sensor.
F48
Not used
F49
OFF*
Leaf slowdown automatic control at opening end ON.
ON
Leaf slowdown automatic control at opening end OFF.
F50
OFF
Door opening/closing speed at high value (standard setting).
ON
Door opening/closing speed at low value (for special applications).
F51
OFF
Door opening speed from the OPEN input (terminal 18): it depends on the setting of the potentiometer P01.
ON
Door opening speed from the OPEN input (terminal 18): at maximum speed, regardless of the setting of the potentiometer P01.
F52
OFF*
Forced closing function OFF.
ON
Forced closing function ON.
When a N.C. contact is connected to the Stop/Interlock input (terminals 14‑19), it allows to forcibly close the door at slow speed after device activation. During this
closing operation, all control and safety inputs are OFF.
Should the forced closing device still be active once the door is closed, the only way to open the door will be using a hold to run command on the OPEN input
(manned mode).
F53
OFF*
The internal and external radars are not active during the closing operation in the work program "Night Lock"
ON
The internal and external radars are active during the closing movement in the “Night Lock” work program, therefore the door is re‑opened.
F54
OFF*
E.C.3 third closure safety sensor input disabled; when the safety sensor is not installed on the input AUX1.
ON
E.C.3 third closure safety sensor input enabled; closure safety sensor on input AUX1 installed.
F55
OFF*
E.C.4 fourth closure safety sensor input disabled; when the safety sensor is not installed on the input AUX2.
ON
E.C.4 fourth closure safety sensor input enabled; closure safety sensor on input AUX2 installed.
F56
OFF*
Operation without mains power supply with battery low: the door operates normally.
ON
Operation without mains power supply with battery low: the door closes and stays closed.
F57
Not used
F58
Not used
F59
Not used
F60
Not used
F61
Not used
F62
Not used
F63
Not used
F64
Not used
F65
Not used
F66
Not used
F67
Not used
F68
Not used
F69
Not used
F70
Not used
F71
Not used
F72
Not used
F73
OFF*
Privacy function disabled.
ON
Privacy function enabled (refer to the paragraph "PRIVACY FUNCTION")
F74
Not used
F75
Function active if
F73 = ON
OFF*
The signaling light (D) is steadily green while the door is moving and waiting for the door lock command.
ON
The signaling light (D) alternately switches between red and green; it flashes slowly while the door is moving, and fast when the door is waiting for the door lock
command.
When the door is closed the light is always steadily red.
F76
OFF*
Closing thrust OFF.
ON
Closing thrust ON to facilitate the release of the electric lock before door opening.
F77
OFF*
Electric lock 12V power supply, standard setting for all the models of electric lock for Eterna.
ON
Electric lock 24V power supply. Warning!!! Not for electric locks of the Eterna range.
Select ON only if you install 24V electric locks (not supplied by Label).
F78
OFF
Holding strength with open door disabled.
ON
Holding strength with open door enabled.
Motor holding voltage when the door is open, to keep the leaves stationary in open position.
F79
Direction of travel: the direction of travel of the door is automatically detected in the phase of initial set‑up.
To reverse door opening direction, change the current state of the function (for example from OFF to ON).
F80
OFF*
Cyclic function OFF
ON
Cyclic function ON.
It activates the continuous door opening and closing cycle; it is used only for operation tests or durability tests.