26) MODULE “UR24”
The module UR24 is an optional interface card provided with a potential free contact C - NO - NC, designed to be inserted into the output
connectors OUT1 and OUT2 of the electronic control unit ET‑LOGIC‑B.
MAX. CAPACITY RELAY CONTACT = 1A ‑ 24Vdc; 0.5A ‑ 120Vac
For module UR24 on the output OUT1, select the desired mode of operation using the function F41m.
WARNING!
If you have selected the interlock function (F27=ON) the output OUT1 operates
as interlock signal and all the functions provided for by F41m are automatically
disabled.
For module UR24 on the output OUT2, select the desired mode of operation using the function F45m.
For each output it is possible to select one of the following functions, described in detail in the functions
table in paragraph "FUNCTIONS AND ADJUSTMENTS":
A = LOCK
Output active with closed contact on the input LOCK 1.
B = GONG
The output activates for 2 seconds to indicate a person crossing the automatic door. Refer to the paragraph "GONG FUNCTION" for
details on the operation.
C = AIR CURTAIN
Air curtain command, device generating a flow of cold or warm air to separate the outside temperature from the inside one.
The output activates when the door is moving or is open, whereas it turns off when the door is closed.
D = BATTERY STATE
The activation of the output reports the status of damaged battery.
E = DOOR STATE
The output reports the state of the door:
OPENING MOVEMENT
= SLOW FLASH
DOOR OPEN
= STEADILY LIT
CLOSING MOVEMENT
= FAST FLASH
CLOSED DOOR
= OFF
F = ALARM WARNING
Output active for 2 seconds if with door closed in NIGHT LOCK program, an opening radar or a safety closing sensor is activated.
G = MAINTENANCE SIGNAL
Output active when the door reaches the number of cycles provided for by the maintenance plan set by the potentiometer P48.
H = STOP SIGNAL
The output activates to signal the activation of the STOP input or of the photocell PRJ38 operating as motor stop sensor for the doors
installed on the escape routes with breakout.