TERMINAL BOARD M
4
(Inputs
10
,
11
,
12
)
The operation of the closing safety sensor
EC1
must be enabled by
dip-switch 1 of S3 = OFF.
If during closing it detects the presence of an obstacle, the door stops and reopens.
If during pause it detects the presence of an obstacle, the door remains open.
11
=
Input Common.
12
= Input of opening safety sensor E.O.1, N.C. contact.
The operation of the opening safety sensor E.O.1 must be enabled by
dip-switch 2 of S3 = OFF
.
The door opens at slow speed if the sensor detects an obstacle during opening
.
The door stops 200 mm from the end of the opening if the opening safety sensor is actived.
10
= Input of
closing
safety sensor E.C.
1
; N.C. contact.
1
6
= STOP
input. Input contact logic state can be set
by dip switch 6 of S2.
Dip switch 7 of S1=OFF: s
top command to stop door motion
.
Dip switch 7 of S1=ON: switch for day / night function selection.
If the input has the contact open, the door works in day mode (active radars).
If the input has the contact close the door works in night mode (disactive radars).
The operation of the closing safety sensor
EC
2
must be enabled by
dip-switch 1 of S
2
= O
N
.
If during closing it detects the presence of an obstacle, the door stops and reopens.
If during pause it detects the presence of an obstacle, the door remains open.
•
TERMINAL BOARD M
3
(Inputs
1
3
,
1
4
,
1
5, 16
)
1
3
=
Input Common
1
4
=
AUX1.
Input of
closing
safety sensor E.C.
2
; N.C. contact.
1
5
=
AUX2.
Input of opening safety sensor E.O.
2
, N.C. contact.
The operation of the opening safety sensor E.O.
2
must be enabled by
dip-switch 2 of S
2
= O
N
.
The door opens at slow speed if the sensor detects an obstacle during opening
.
The door stops 200 mm from the end of the opening if the opening safety sensor is actived.
2
4
Summary of Contents for ETERNA 90 EASY
Page 47: ...47 notes ...