45
2
1) MEANING OF BUZZER WARNING SIGNALS
The ET-LOGIC-
EASY
control unit of the automation is equipped with a buzzer emitting a set of warning signals, whose meaning
varies according to the number of emitted beeps and to the signal duration.
WARNING SIGNAL (BEEP)
MEANING
5 short and fast BEEPS
Automation not set-up when powered.
4 BEEPS
Intervention on the PRJ38 photocell.
4 short BEEPS
Set-up cycle initial phase starting warning.
Extended sound (3 seconds)
Signals the end of the initial set-up.
Extended and intermittent sound
(during motion)
The power limit that the automation can supply to the motor is
exceeded while the leaf is in motion.
1 BEEP
After powering the automation (already started up before).
1 BEEP (before the opening)
Failed opening safety sensor test.
1 BEEP (before the opening)
Battery failure or low battery charge warning.
2 BEEPS (when the door is open)
Failed closing safety sensor test.
1 extended BEEP (1")
Detection of an internal system failure.
2
2) MAINTENANCE PROGRAM
To ensure that the automatic door keeps running safely over time, we recommend to carry out the maintenance operations once every
6 months.
Warning!
Before performing any operation on the automation, cut off the mains power supply.
•
Check that all screws are tight.
•
Check the belt's tension.
•
Clean the carriage sliding rail and the ground sliding guide.
•
Check that carriages and leaves are properly aligned and that the door's final ledge is in correct position.
•
Check that the electric lock - if any - is properly fastened and that the mechanical release device operates properly.
•
Check connections and electric cables
•
Check leaf stability and make sure that movement is smooth and frictionless along the whole run.
•
Check that motion speeds, involved forces, and installed safety devices are working appropriately.
•
Clean sensors and check that presence detectors activate properly.
Warning!
Any potentially damaged or worn component must be replaced.
Make use only of original spare parts; for this purpose check LABEL Parts list.
4 BEEPS
Intervention on the
STOP command.
Summary of Contents for ETERNA 90 EASY