52
SYMBOL MESSAGE ON DISPLAY
SYMBOL
MESSAGE ON DISPLAY
ACTION
WARNINGS
ERRORS
Massages which may be displayed in cells E1 through E5
You need to turn the main 230V power supply OFF and
then ON again after a few seconds.
If the problem persists it is a defect on the ET-LOGIC-B
control unit.
Check that the leaf slides properly and that there are no
obstacles along the path it follows; also check that motor
and encoder are connected, then repeat the set-up attempt.
You need to turn the main 230V power supply OFF and
then ON again after a few seconds.
Check that the motor runs, that the motor and encoder
connectors are properly plugged in and that the encoder
and motor cables are not damaged.
The operator has not managed to
complete the initial set-up.
You need to turn the main 230V power supply OFF and
then ON again after a few seconds.
If the problem persists it is a defect on the ET-LOGIC-B
control unit.
The system restores automatically after a few seconds
and carries out an other testing attempt.
If the problem persists it is a defect on the ET-LOGIC-B
control unit.
Failed cyclic internal test of the current
detect circuit.
CURRENT FAULT
POWER FAULT
INITIAL SETTING
ERROR
ENCODER OR
MOTOR ERROR
OPENING SAFETY
SENSOR ERROR
CLOSING SAFETY
SENSOR ERROR
BATTERY FAULT
BATTERY FAULT
EEPROM REGISTER FAULT
The motor piloting signal test has detected
a fault.
Signals from the encoder are not
detected.
Failed opening safety sensor test.
Failed closing safety sensor test.
The system signals a damage to the
battery.
Failed internal memory register test.
OPENING OBSTACLE
CLOSING OBSTACLE
The door has come into contact with an
obstacle while closing; this caused the
motion direction to be reversed.
The door has come into contact with an
obstacle during opening; this caused the
motion direction to be reversed.
If the problem persists, remove the obstacle or
check that the leaf slides properly.
If the problem persists, remove the obstacle or
check that the leaf slides properly.
Check that the test settings and parameters are
correct, that the test has also be enabled on the
safety sensor and that the electrical connections
between sensor and control unit are correct.
Check that the test settings and parameters are
correct, that the test has also be enabled on the
safety sensor and that the electrical connections
between sensor and control unit are correct.
During operation the battery is constantly monitored.
Should the system signal any damage to it, check
that the battery and the battery charger board are
working properly.
MEANING
MEANING
EVENT MEMORY
PROBLEM RESOLUTION
ERROR
CODE
01
02
ERROR
CODE
33
34
35
36
37
38
43
44
FAULT PRJ38
Failed PRJ38 to photocell test
The photocell PRJ38 is faulty.
Replace the PRJ38.
41
39
40