11) PROGRAM SELECTORS
The program selector allows the user to select the operating mode of the door.
You can use the following devices, depending on the choice made: manual selector integrated into the automation side of NEXT 120S,
mechanical key selector EV-MSEL and digital selector ET-DSEL or digital selector T-NFC.
Each program selector is fully described below.
11.1) MANUAL PROGRAM SELECTORS
The 3-position manual program selector built into the automation is the basic solution. The operation of this selector is enabled when the
function F01 is OFF (default).
Position
I
=
Automatic bidirectional program
The door automatically opens after an opening command.
Position
0
=
Manual free door
Automatic operation is disabled and the door can be opened manually.
Position
II
=
Night lock program
The door can only be opened by the OPEN input or by radio control if the radio
receiver is installed.
Open door program
The door stops in fully open position.
11.2) MECHANICAL KEY SELECTOR EV-MSEL
The 5‑position mechanical key selector can be used as an alternative to
the manual selector, and its operation is enabled when the function F01
is OFF (default).
Disconnect the wires of the manual selector from the
terminal box of the control unit NEXT-L120S if you
have installed the mechanical selector EV-MSEL.
ELECTRIC CONNECTIONS
Terminal 1 of EV‑MSEL= to terminal 2 (Internal radar) of the control unit NEXT‑L120S.
Terminal 2 of EV‑MSEL= to terminal 0 (Common) of the control unit NEXT‑L120S.
Terminal 3 of EV‑MSEL= to terminal 5 (AUX 1) of the control unit NEXT‑L120S.
Terminal 4 of EV‑MSEL= to terminal 4 (AUX 2) of the control unit NEXT‑L120S.
For any check on proper connection and operation of the key mechanical selector, enter inputs diagnostics (see
par. 10.5) to ensure that different key positions correspond to the activation of the following symbols:
=
and
=
no active symbol
=
=
and
=
OPERATING MODE
Insert and turn the key of the selector EV-MSEL to select the desired program.
Open door program
The door stops in fully open position.
Manual free door
Automatic operation is disabled and the door can be opened manually.
Automatic bidirectional program
The door automatically opens after an opening command.
Only unidirectional automatic program output
To disable entry detection on external Radar input.
Night lock program
The door can only be opened by the OPEN input or by radio control if the radio receiver is installed.
The key can be removed from the selector in any position in order to prevent unintentional changes.
if function F06 is
set to
OFF
(default)
if function F06 is
set to
ON