LM1012TTS Table-Top Label Applicator System
USER'S MANUAL
Made in the U.S.A.
© 2022 LABELMILL
01/01/2022 Model LM1012TTS
Page 20
PASSWORD
The PASSWORD is used to lock the menus of the control. This option is used to prevent unauthorized access to
variable data. When shipped from the factory, the password is to 7074 and NO MENUS are locked. The factory
password cannot be changed. An alternate user password can be set to lock specific menus in the control.
I/O STATUS
Displays the status of the inputs and outputs.
AUTO SET GAP
***NO LONGER USED IN SYSTEMS MANUFACTURED AFTER 2020***
The AUTO SET GAP function is used to set label sensor values. (Note that when using a Clear label detector the sensor
values are not relevant) The label speed (IPM) can be set to fine tune this option. It is recommended to leave the IPM
set to 300 or set it at the current application speed.
PRODUCT SENSOR
This is an external device that when “activated” starts the application cycle.
PROGRAMMABLE BLOCKS:
Product Delay
– Delays the application of the label (x) seconds after the sensor has been activated.
Sensor Trigger
– Programs system to be activated at the leading or trailing edge of the trigger signal.
On Debounce - Programs how long (seconds) a trigger signal must be received to activate system.
Off Debounce - Used to ignore trigger signals (in seconds) after a cycle has completed.
Multiple Feed
– Programs how many system cycles occur with a single trigger signal.
Interval Delay
– Amount of time in seconds between multiple fed labels. Note: Active with quantity 2+
TAMP SETUP
This is used to adjust the different variables related to the tamp cycle.
PROGRAMMABLE BLOCKS:
Tamp Duration
– Used to adjust the time that the tamp cylinder valve is actuated.
Flag Duration
– Used to adjust the time the flag jaws are held open after label application.
Head Up Limit Switch
– Type:
normally open-
standard, normally closed, none
Head Up Debounce
– Debounce is used to allow time for the tamp cylinder to settle on return.
Vacuum Release
– Used to release label when tamping on light products.
Vacuum Delay On
– Used to reduce label flutter when feeding large labels onto the vacuum platen.
Tamp Sync - Used for "Normal" or "Reverse" Tamp signal operation.
ROUND MODULE SETUP
This is used to adjust the system parameters when using the Round Module attachment.
PROGRAMMABLE BLOCKS:
Roller Stop Delay - Delays the wrap roller from stopping after the label feed.
Label Feed Delay - Delays the start of the label feed after the carriage pivots up.
Roller Speed - Used to program how fast the Round Module rotates.
Roller Acceleration - Used to control how fast the motor reaches the programmed speed.
Jog Round Motor - Used to manually jog the motor on the Round Module.
LABEL SPEED
PROGRAMMABLE BLOCKS:
Label Speed
– Used to control the speed that the label is fed through the system
Label Acceleration - Used to control how fast the motor reaches the programmed feed speed.