Tamp Module Setup
Tamp pad adjustment
1. To adjust the tamp pad (T) in relationship to the peeler plate (P) in the horizontal
plain, loosen the thumbscrews (S) and move the tamp module forward or
backward in the slots. There should be approximately .020" (A) gap
between the tamp pad (T) and the peeler plate (P). The tamp pad (T) can
also be adjusted left to right in relation to the peeler plate (P) via the
slot in the top of the crossbar (D).
NOTE:
The center of the tamp pad
should be at the center of the label.
2. To adjust the tamp pad (T) in relationship to the peeler plate (P) in the
vertical position, loosen the mounting screw (M) and adjust the vertical
screws (V) in or out to achieve the .020" (B).
NOTE:
The tamp pad (T)
must maintain parallelism with the peeler plate (P).
Air assist tube adjustment
1. Adjust the air-assist tube (B) so that the small holes aim towards the center of the label as shown by the arrowhead (F)
shown above. The air assist tube (B) aids the label (L) to adhere to the bottom of the tamp pad (T). Once the label (L) is
“blown” onto the tamp pad (T), it is held there by vacuum.
2. Once the above adjustments are made, adjust the vacuum regulator, the air assist regulator, and the flow controls as
needed.
Note: Too much pressure on the air assist will cause the label to flutter and/or blow off of the vacuum platen.
Crossbar (D)
Vertical Set Screw (V)
Tamp Pad (T)
Rail (C)
Air Assist Tube (B)
Peeler Plate (P)
Thumbscrew (S)
Label (L)
Airflow (F)
Mounting Screw (M)