LM1012TTS Table-Top Label Applicator System
USER'S MANUAL
Made in the U.S.A.
© 2022 LABELMILL
01/01/2022 Model LM1012TTS
Page 41
Flag Applicator Module Installation
The Flag Applicator Module shown below can be installed in a few minutes to the existing LM1012TTS system dispenser
unit.
ACTIONS TO INSTALL FLAG MODULE
1. Set the main power switch to the OFF position.
2. Disconnect the AC power cable from the rear of the console.
3. Remove any installed module or dispenser photo-eye mounted to the guide rails.
4. Carefully slide the flag module on to the rails until the unit is in the proper position (following Tamp Module Setup).
5. Install and tighten the mounting knobs through the slotted holes on either side of the mounting rails.
6. Install the cable from the valve assembly into the connector on the accessory panel of the control box tagged
“SOLENOIDS”, if it is not already connected.
7. Install the cable from the tamp module head up switch into the connector on the accessory panel of the control box
tagged “HEAD UP/AUX”.
8. Install the six (6) airlines fitted with quick disconnect style fittings on the manifold plate above the solenoids. They are
marked 1, 2, 3, 4, 5, and 6.
9.
Install the cable into the connector on the accessory panel of the control box tagged “REMOTE TRIGGER” (Foot Switch,
Palm Button, or Trigger Switch).
10. Connect the power cable and turn the unit on.
11. Program the control Cycle Type for Tamp (Before or After Feed).
12. Program the Tamp Duration in the Tamp Setup Menu.
13. Program the Flag Duration in the Tamp Setup Menu.
14. Program the Head Up Switch to N.O. in the Tamp Setup Menu.
15. Adjust the label sensor, and label speed until both are functioning properly.
16. Adjust the flag jaw pressure on the Flag Valve of the Valve Pack. To adjust the jaws, start with the pressure low and
increase pressure as needed to achieve proper wrap of the label on the product.
NOTE: Low pressure will not close the jaws, and high pressure will not label consistently or may cause product
breakage.