LM1012TTS Table-Top Label Applicator System
USER'S MANUAL
Made in the U.S.A.
© 2022 LABELMILL
01/01/2022 Model LM1012TTS
Page 48
Module Air Connections
Module Air Hose Connections
1. After installing one of the 3 modules, connect the airlines (A) to the Manifold Plate (D) shown above.
2. The Air Line Numbers (C) should be matched with the numbers on the Manifold Plate (D).
3. To connect the Air Line (A) to the Manifold Plate (D), simply push the male connector of the Air Line (A) into the Female
Coupler (E). It will “snap”, automatically “locking” it into place. NOTE: If the male connector of the Air Line (A) won’t slide
easily into the Female Coupler (E), it may be necessary to push the Release Tab (B) towards the center of the plate,
locking the tab in the “open” position.
4. To release the Air Line (A) from the Manifold Plate (D), simply push the Release Tab (B) towards the center of the plate
and remove the Air Line (A).
Manifold Plate (D) Number Reference
1) Vacuum
2) Air Assist
3) Tamp Cylinder Down / Bottle Roller Carriage Up
4) Tamp Cylinder Up / Bottle Roller Carriage Down
5) Flag Jaws Open
6) Flag Jaws Closed
Manifold Plate (D)
Air Line (A)
Female Coupler (E)
Release Tab (B)
Air Line Number (C)