Installation

Important note: attention is drawn to the General Safety Precautions Panel on page 4 which 

contains advice on safe installation and operation of these products.

 

Location

Choose a location for the amplifier from which it is convenient to run cables from the  

antennas and to the system outlets. Typical examples of suitable locations are a loft space or a 

cupboard. In weak signal areas it is best to keep the antenna cables as short as possible.

Select a cool, dry location to install the amplifier. This means a location where the ambient 

temperature will remain between -10°C and +40°C, and which is free from risk of dripping or 

splashing water.

The fixing location should allow adequate access to the equipment for wiring and maintenance. 

Clearance of at least 25mm should be allowed around the top and left hand side of the amplifier 

and also around the three sides of the power supply that don’t have connections to allow  

adequate ventilation. More clearance will be needed on the sides with connections to allow 

access for cables. 

 

Fixing 

The amplifier should be fixed to a wall or other suitable hard surface, using suitable screws and 

masonry plugs (not supplied). The amplifier should not be left supported by its own wiring, nor 

should it be left resting on a carpet or other insulating and/or inflammable surfaces.

 

Electricity Supply

Fixed wiring and connection of the electrical supply to these products should be carried out in 

accordance with BS7671 (IEE Wiring Regulations) .

Each amplifier is supplied with a separate PSUF fitted with a 13A mains plug. If this is not 

suitable, see General Safety Precautions Panel on page 4. As an alternative to the use of plug 

and socket connection, the power supply may be connected to the mains using a switched 

fused connection unit BS 1363-4. A 3 Amp fuse to BS1362 should be fitted in the fused 

connection unit. If the power unit is connected to the supply other than by means of its fitted 

fused plug or a fused connection unit, It must be protected by a non-time delayed fuse or a 

type B MCB at the distribution board of rating not exceeding 6A. An isolating switch should be 

provided near to the unit to allow it to be disconnected from the supply when necessary.

 

Signal Connections

Input and output signal connections are made using F type (IEC 60169-24) connectors.  

Good quality plugs should be used, preferably of the crimp on type. If twist on connectors are 

used make sure they are the right size to fit the cable you are using. For outside connections 

use  waterproof connectors

. Attention is drawn to the need to maintain DC continuity through-

out the system for correct operation of infra-red remote control functions

 

Resetting RF Channel on a Digibox 

1. 

Switch on your Sky™/Sky+™/ Sky+ HD™ receiver and view on your main television.

2.

 Press  the 

SERVICES 

button on your Sky™ remote

.

3.

 Select 

SYSTEM SETUP 

option 

(for SKY+ HD there is no SYSTEM SETUP 

option 

press 0 instead)

.

4.  

Press the following buttons in sequence:  

0,  1,  SELECT (for SKY+ HD this is a hidden option 

and does not appear on screen).

 You should now see the installers’ menu.  

5.

 Select the 

RF CHaNNEL NUMbER

 option and key in a new channnel number from 21-58.  

  Make a note of the channel number you choose as you may need it when tuning your  

  other TVs.

3

2

Amplifier

LDL206LP

LDL208LP

No of Inputs

2

No of Outputs

6

8

Return Path Frequency Range

5-15MHz

5-15MHz

Return Path Gain

-4dB

Frequency Range

UHF: 470-790MHz  FM/DAB: 47-300MHz

UHF/FM/DAB Gain per port

8dB

Max Out put level (IMA3-60dB). EN50083-5

98dBµv

96dBµv

Noise Figure

3.5dB

All Ports IR Enabled

9V 15mA short circuit protected

Isolation between outlets

20dB

Dimensions

265 x 95 x 35mm

Power Supply

PSUF

DC Output

12VDC at 200mA max.

Output Voltage Tolerance

± 5%

Power Requirement

220-240V~50Hz at <3W

Signal Insertion Loss

0.5dB

Dimensions

 88 x 67 x 45mm

Installation Instructions