OUT 1
IN
Power pass
PSW111
TV outlet
PSUFC
TV
Specifications
LMA113R
LMA209R
LMA125VR
LMA415VR
No of Inputs / Outputs
1 / 1
1 / 2
1 / 1
2 / 4
Frequency Range
470-782MHz
470-782MHz
87-230/470-782MHz
Gain per port
13dB
10dB
12-25dB
0-15dB
Noise Figure
Typ. <2dB
Typ. <2dB
Typ. <2dB
Typ. <2dB
Max Output level (IMA3-60dB)
98dBµv
94dBµv
101dBµv
94dBµv
Isolation between outlets
N/A
22dB
N/A
22dB
RED, EMC and LVD
Compliant
Compliant
Power Requirement
12V DC 30mA
12V DC 60mA
Power Supply
PSUFC
DC Output
12VDC - Voltage tolerance 5% - Current 300mA max
Power Requirement
220-240V~50Hz at <3W
Signal Insertion Loss
0.5dB
Typical Installation and Specifications
COMPLIANT
2
General Safety Precautions
• To avoid risk of electric shock during
installation we recommend that the power
unit and all associated TV receivers, etc.
are isolated from the mains until the
installation is complete.
• Fixed wiring for electrical supply to these
products should be carried out in
accordance with BS7671 (IET Wiring
Regulations).
• Distribution systems supplying signals to
more than one household should comply
with the safety requirements of BS EN60728-11.
This requires the system to be earth bonded
or the use of isolated outlets.
• If you are in any doubt about an installation,
refer to a qualified aerial installer.
• When working on an installation outside,
beware of overhead power lines.
• Observe safe working practices, tread carefully
and ensure adequate lighting is available
in loft or roof space.
• Always follow manufacturer’s operating/safety
instructions when using tools/ equipment.
• Only carry out work outdoors at height if you
are competent in the use of ladders and
related access equipment.
• Always read and follow the manufacturer’s
instruction label affixed to the ladder.
Typical Connection
Power LED
Adjustable
gain contro
l
Fig. 1