Transport and storage conditions

Ambient temperature: -40 °C to +40 °C
Relative humidity: 30% to 75%
Air pressure: 500 to 1060 hPa.

If the device cannot be operated safely anymore, it must be removed from operation and protected from 
unintentional or unauthorised operation. In order to rule out damages caused by the transport, a visual in-
spection of the device should be performed prior to the initial operation. Please note: The device may be 
transported in the original or an equivalent packaging only.

Technical parameters

Symphony hygiene module handpiece

Rated voltage: 12 V – (DC)
Power input: 1.5 W max
Operating conditions:
Ambient temperature: +10 °C to +35 °C
Relative humidity: 30% bis 75%
Operating frequency: 50-140 stitches per second
Drive: Precision engine - DC
Operating mode: continuous operation
Length, diameter: 135 mm, 19 mm
Overall weight: 400 g
Weight of the handpiece: approx. 50 g

LaBina

®

 PL-500 Control pigmentation instrument

Art-No: LaBina-PL500-Control

Control unit

Rated voltage: 15 V – (DC)
Power input: 7 VA max
Wall wart: as stated on the type plate
Level of protection: 2
Operating conditions:
Ambient temperature: +10 °C to +35 °C
Relative humidity: 30% to 75%

17

Supplies

For the Symphony hygiene module hand-
piece of the LaBina

®

 PL-500 Control the 

hygiene modules listed on the left are 
required. Every unit contains 15 hygiene 
modules.

Manufacturer:

MT.Derm GmbH
Gustav-Krone-Straße 3  14167 Berlin
Germany

Distributor and vendor for devices,  
accessories and supplies

PERMANENT-Line GmbH & Co. KG

Mengeringhäuser Str. 15 
34454 Bad Arolsen, Germany

Telephone:  +49 (0)5691 8953-0 
E-Mail:      Info@LaBina24.de
Internet:    www.Labina24.de

Description

Art-No:

1st-Liner hygiene module

E-0401

1st-Micro hygiene module

E-0401C

1st-Nano-N1-Hygienemodule

E-0401N1

1st-Nano-N2-Hygienemodule

E-0401N2

3rd-Liner hygiene module

E-0403

3rd-Outline hygiene module

E-0430

3rd-Slope hygiene module

E-0403S

4th-Flat hygiene module

E-0404

5th-Shader hygiene module

E-0405

5th-Magnum hygiene module

E-0405M

5th-Slope hygiene module

E-0405S

7th-Round hygiene module

E-0407

9th-Magnum hygiene module

E-0409

Microlift module needle plate

E-MM00020

Summary of Contents for PL-500 Control

Page 1: ...User s manual LaBina PL 500 Control www LaBina24 de...

Page 2: ...rator is obliged to comply with the principles of cleanliness and hygiene as well as to utilise so lely sterile disinfected materials Further information is provided in the chapter important hygiene a...

Page 3: ...nnot be guaranteed Sup plies must not be used after the expiration date The brackets and protective caps of the handpiece must also be cleaned and disinfected immediately before the treatment of every...

Page 4: ...signs of damage if the device does not run properly after a long period of storage beyond the mandatory temperature range in case of damages caused by improper transport The device should be transferr...

Page 5: ...5 N H F E K P M A K G B D Rear of the control unit Front of the control unit...

Page 6: ...sidues or scars could remain after the remo val During the first 4 to 6 weeks the intensity of the injected pigments is reduced to the permanent level This is usual as the epidermis upper skin layer i...

Page 7: ...stored in the original packaging Utilisation of pigments The module must be filled with 2 to 3 drops of colour Alternatively the tip of the module can be immersed into the colour for 2 to 3 seconds Th...

Page 8: ...www Labina24 de...

Page 9: ...Lip contour and fine inward lip shading Test point for allergy tests 1st Micro hygiene module 0 18 mm Needle Art No The needle diameter of the 1st Micro hygiene mo dule similar to the 1st Liner hygien...

Page 10: ...ely and are bundled closer to each other Practical tip Due to the closer bundling the 3rd Outline needle is not perceived to be as sharp as a 1st needle It enters the skin particularly well and traces...

Page 11: ...shading Shading of lip edges in case of narrow lips Shading of full lips 3rd and 5th Slope hygiene module 0 4 mm Needle Art No In a sloping needle type 3 or 5 needles are aligned side by side at an a...

Page 12: ...e of needles the customers experience less pain Ideal colour injection and shorter treatment time PL 500 Control E 0407 Application Broader lip contour Colour filling of the lips Areola and scars 9th...

Page 13: ...A make up that accompanies you regardless which weather...

Page 14: ...nd the device must never be directly soaked in a desinfectant agent as this may cause inner parts to corrode If a protective cap is used for storage purposes during a treatment the protective cap must...

Page 15: ...ciousness dizziness Particular caution is necessary in the following cases If the patient suffers from herpes simplex a pigmentation of the lips usually causes herpes labialis cold sores A prior consu...

Page 16: ...d oxidising acids e g peracetic acid lyes e g sodium hydroxide ammonia all substances with a pH level higher than 7 aromatic halogenated hydrocarbons e g phenol chloroform as well as acetone and petro...

Page 17: ...Control unit Rated voltage 15 V DC Power input 7 VA max Wall wart as stated on the type plate Level of protection 2 Operating conditions Ambient temperature 10 C to 35 C Relative humidity 30 to 75 17...

Page 18: ...device that is free of charge for the duration of the repair Distribution PERMANENT Line GmbH Co KG Complementary PERMANENT Line Schneider Kosmetik GmbH Mengeringh user Str 15 34454 Bad Arolsen Deutsc...