Hygiene module

For the use of the hygiene module the chapters “important hygiene and safety instructions” have to be con-
sidered.

A label attached to each module states the batch 
number, as well as the production and expiration 
dates. The batch number enables the identifica-
tion of the precise batch and has to be communi-
cated to the manufacturer in case of issues. This 
number has to be noted in the customer file. The 
manufacturer guarantees the sterility for 5 years if 
the packaging is closed and undamaged and if the 
conditions in the chapter “Shipment and storage 
requirements” are met. The modules have to be 
stored in the original packaging.

Utilisation of pigments

The module must be filled with 2 to 3 drops of colour. Alternatively, the tip of the module can be immersed 
into the colour for 2 to 3 seconds. The colour is sucked in when the device is switched on. Contact with the 
paint container must be avoided.

Adjustment of needle stand-out

The adjustment of the penetration depth must be performed while the device is switched on. In order to  
adjust the stand-out of the needle, the handpiece has to be hold at the rear section of the pen. The needle 
can be adjusted individually by screwing the front section of the hygiene module with the second hand. 

The correct stand-out of the needle depends on the respective treatment, the skin type, the desired effect 
and other factors. This know-how is gained during training. 

7

Summary of Contents for PL-500 Control

Page 1: ...User s manual LaBina PL 500 Control www LaBina24 de...

Page 2: ...rator is obliged to comply with the principles of cleanliness and hygiene as well as to utilise so lely sterile disinfected materials Further information is provided in the chapter important hygiene a...

Page 3: ...nnot be guaranteed Sup plies must not be used after the expiration date The brackets and protective caps of the handpiece must also be cleaned and disinfected immediately before the treatment of every...

Page 4: ...signs of damage if the device does not run properly after a long period of storage beyond the mandatory temperature range in case of damages caused by improper transport The device should be transferr...

Page 5: ...5 N H F E K P M A K G B D Rear of the control unit Front of the control unit...

Page 6: ...sidues or scars could remain after the remo val During the first 4 to 6 weeks the intensity of the injected pigments is reduced to the permanent level This is usual as the epidermis upper skin layer i...

Page 7: ...stored in the original packaging Utilisation of pigments The module must be filled with 2 to 3 drops of colour Alternatively the tip of the module can be immersed into the colour for 2 to 3 seconds Th...

Page 8: ...www Labina24 de...

Page 9: ...Lip contour and fine inward lip shading Test point for allergy tests 1st Micro hygiene module 0 18 mm Needle Art No The needle diameter of the 1st Micro hygiene mo dule similar to the 1st Liner hygien...

Page 10: ...ely and are bundled closer to each other Practical tip Due to the closer bundling the 3rd Outline needle is not perceived to be as sharp as a 1st needle It enters the skin particularly well and traces...

Page 11: ...shading Shading of lip edges in case of narrow lips Shading of full lips 3rd and 5th Slope hygiene module 0 4 mm Needle Art No In a sloping needle type 3 or 5 needles are aligned side by side at an a...

Page 12: ...e of needles the customers experience less pain Ideal colour injection and shorter treatment time PL 500 Control E 0407 Application Broader lip contour Colour filling of the lips Areola and scars 9th...

Page 13: ...A make up that accompanies you regardless which weather...

Page 14: ...nd the device must never be directly soaked in a desinfectant agent as this may cause inner parts to corrode If a protective cap is used for storage purposes during a treatment the protective cap must...

Page 15: ...ciousness dizziness Particular caution is necessary in the following cases If the patient suffers from herpes simplex a pigmentation of the lips usually causes herpes labialis cold sores A prior consu...

Page 16: ...d oxidising acids e g peracetic acid lyes e g sodium hydroxide ammonia all substances with a pH level higher than 7 aromatic halogenated hydrocarbons e g phenol chloroform as well as acetone and petro...

Page 17: ...Control unit Rated voltage 15 V DC Power input 7 VA max Wall wart as stated on the type plate Level of protection 2 Operating conditions Ambient temperature 10 C to 35 C Relative humidity 30 to 75 17...

Page 18: ...device that is free of charge for the duration of the repair Distribution PERMANENT Line GmbH Co KG Complementary PERMANENT Line Schneider Kosmetik GmbH Mengeringh user Str 15 34454 Bad Arolsen Deutsc...