|        LABNET 311DS SHAKING INCUBATOR

1.4 Specifications

Dimensions (W x D x H)

6.75 x 12.75 x 14.25 in. (17.1 x 32.4 x 36.2 cm)

Weight

27 lbs. (12 kg)

Sealing Temperature

Off, 100°C to 190°C (increments of 1.0°C)

Temperature Accuracy

±1.0°C

Temperature Uniformity

±1.0°C

Sealing Time

0.5 to 10 sec. (increments of 0.1 sec.)

Compatible Plate Materials

 



PP (Polypropylene)

 



PS (Polystyrene)

Compatible Plate Types

 



Standard assay plates

 



Deep well storage plates

 



PCR plates: skirted, semi-skirted, non-skirted

Maximum Plate Height

1.77 in. (4.5 cm)

Compatible Sealing Film Types

 



Foil polypropylene laminate

 



Clear polyester-polypropylene laminate

 



Clear polymer

 



Thin clear polymer

 



Foil laminate

 



Foil

Electrical Requirements 
   PS1000 
   PS1000-230V

 
120V ±10%, 50/60 Hz, 450W, 3.15A 
230V ±10%, 50/60 Hz, 450W, 2A

Overvoltage Category

Category II

Environmental Conditions

15°C to 30°C, ≤80% RH

Storage Temperatures

0°C to 60°C

The Labnet AccuSeal™ semi-automated plate sealer is designed to be safe at least when operated under the following conditions:

 



Indoor use

 



Altitude up to 2,000 meters

 



Pollution Degree 2

Product should be placed on a flat surface at least 12 in. (30.5 cm) from walls, 48 in. (122 cm) from ceilings, and 12 in. (30.5 cm) from 

other equipment.

 2.0  Getting  Started

2.1 Installation

1.  Unpack the instrument carefully and place on a level stable surface that can withstand its weight. Do not block ventilation 

openings on the back.

2.  Remove and identify all components from the box.

 



Power cord

 



Seal frame

 



Plate sealer

 



PCR plate adapter block for 96- or 384-well microplates 

 



Support block for storage plates

 



Instruction manual

3.  Remove the protective plastic bag and any protective film.
4.  Plug the power cord into the back of the instrument, and plug the other end into a properly rated outlet. Confirm the voltage rating 

listed on the instrument is properly labeled to 110V or 230V as required.

5.  Always use PPE, gloves, eye-wear, etc. accordingly to your experiment protocols’ requirements.
6.  Switch the main power to ON.
7.  The front control panel display will illuminate.

Summary of Contents for AccuSeal PS1000

Page 1: ...Labnet AccuSeal Semi automated Plate Sealer Instruction Manual Catalog Numbers PS1000 PS1000 230V ...

Page 2: ...1 Installation 2 2 2 Display Overview 3 2 3 Unit Overview 3 3 0 Operation 4 3 1 Set the Temperature 4 3 2 Set the Time 4 3 3 Using Plate Adapters 4 3 4 Using the Seal Frame 4 3 5 Sealing a Plate 5 3 6 Accessing and Cleaning the Heating Platen 5 3 7 Power Save Mode 6 4 0 Troubleshooting 6 4 1 Error Codes 6 5 0 Limited Warranty 7 6 0 Equipment Disposal 7 ...

Page 3: ...uction manual contains important operating and maintenance instructions which must be read understood and followed by the product user Failure to use this product according to this instruction manual may degrade or defeat the protection normally provided by this product Read this instruction manual prior to product use Personal Injury Do not use this product in a manner other than as stated in the...

Page 4: ... plate sealer is designed to be safe at least when operated under the following conditions Indoor use Altitude up to 2 000 meters Pollution Degree 2 Product should be placed on a flat surface at least 12 in 30 5 cm from walls 48 in 122 cm from ceilings and 12 in 30 5 cm from other equipment 2 0 Getting Started 2 1 Installation 1 Unpack the instrument carefully and place on a level stable surface t...

Page 5: ...settings by rotating left or right 4 Seal Button Used to initiate the sealing process Can also be used to cancel sealing before the drawer is closed 5 Status Indicator Light Light will illuminate Red Unit not at set temperature Green Unit is ready 6 Open Close Opens or closes the drawer 7 Motorized Drawer Opens for plate insertion or extraction Open Close button allows for opening and closing 1 Ve...

Page 6: ...rawer closed and without a sample plate on the drawer while the platen is heating up This will allow the unit to heat to the set temperature more quickly 3 2 Set the Time Pressing the Mode button until the Seal Time text is flashing Use the control knob to adjust the display to the desired sealing time Press the control knob or wait 10 seconds to set the selected time 3 3 Using Plate Adapters Labn...

Page 7: ...the Seal button The drawer will close automatically the plate will be sealed and the drawer will open for removal of the seal frame and plate Sealing a Plate 1 Set the Sealing temperature and time 2 Insert the Adapter if required 3 Place the plate in the drawer 4 Place the seal on top of the plate 5 Place the sealing frame on top of the seal 6 Press Seal when the light is green drawer will close s...

Page 8: ...and moving out of position Temperature difference and electrostatic charge affecting the seal Use the sealing frame to secure the seal in place Sealing film is sticking to platen Foreign material stuck to the platen Follow the procedure for cleaning the heating platen 4 1 Error Codes Code Possible Cause Solution Error 1 Tray motor or switch failure Reboot the unit Error 2 Error 3 Heater motor or s...

Page 9: ...s or contact your local support office Corning s Customer Service team will help arrange local service where available or coordinate a return authorization number and shipping instructions Products received without proper authorization will be returned All items returned for service should be sent postage prepaid in the original packaging or other suitable carton padded to avoid damage Corning wil...

Page 10: ...N AMERICA grupoLA corning com Brazil t 55 11 3089 7400 Mexico t 52 81 8158 8400 To request certificates please contact us at www labnetlink com Warranty Disclaimer Unless otherwise specified all products are for research use or general laboratory use only Not intended for use in diagnostic or therapeutic procedures Not for use in humans These products are not intended to mitigate the presence of m...

Reviews: