  Operation Manual contains information on specifications, the device and the operating prin-
ciples, the rules of storage, instructions for use and maintenance, necessary for the proper 
operation and full usage of the technical capabilities of the voice recorder "SOROKA-06E". 
 

 

Fig. 1. Scopes of delivery of the voice recorder "SOROKA-06E": 

Table 1. List of items supplied 

Name 

Number 

SOROKA-06E 

Voice Recorder "SOROKA-06E" 

USB Cable to charge the internal accumulator 

AC adapter with USB output 

The adapter to charge the external battery 

External power cable with a built-in stabilizer  

(U

inp

 = 5..28V) 

External Accumulator 

1.8 Ah 

Cable with one external microphone 

Cable with two external microphones (stereo) 

Memory Card micro SD / SDHC 

32 GB 

Card Reader 

Passport 

Package 

 

 
 
 

Summary of Contents for SOROKA-06E

Page 1: ...Laboratory 2 LTD Version of 12 05 2020 Page 1 DIGITAL VOICE RECORDER MEMS SOROKA 06E Manual ...

Page 2: ...2 2 Charging the internal accumulator 7 2 3 Charging the external accumulator 7 2 4 Setting parameters of the voice recorder 7 2 5 Usage of the voice recorder 8 2 6 Selection of operation from the external microphones and mono stereo recording mode 8 2 7 Creating a configuration file of the voice recorder 9 3 The system of tags of the voice recorder soroka 06E 13 4 Description of items for externa...

Page 3: ...KA 06E Fig 1 Scopes of delivery of the voice recorder SOROKA 06E Table 1 List of items supplied Name Number SOROKA 06E Voice Recorder SOROKA 06E 1 USB Cable to charge the internal accumulator 1 AC adapter with USB output 1 The adapter to charge the external battery 1 External power cable with a built in stabilizer Uinp 5 28V 1 External Accumulator 1 1 8 Ah Cable with one external microphone 1 Cabl...

Page 4: ...ingmax memory card 16 GB 10 cl The frequency of dis cretization Typical operating time hours Not less than hours Mono Stereo Mono Stereo 8 kHz 16 bit 42 21 25 13 16 kHz 16 bit 25 13 15 8 8 kHz 8 bit u law 52 26 31 16 16 kHz 8 bit u law 31 16 19 10 14 Length of continuous recording with an external accumulator 1 8 A h 8 kHz 8 bit Up to 670 hours 28 days 15 Function of real time clock Yes 16 Functio...

Page 5: ...s only possible by only briefly pressing the button after opening the file b Recording mode from the inter nal microphone after the brief pressing of control button 1 If the accumulator voltage is normal the indicator flashes green 8 times 2 If the accumulator is low the indicator flashes 8 times red c Recording mode from external microphones microphone after brief pressing control button 1 If the...

Page 6: ...nal battery Charging mode Status Indicator Charge с End of charge The indicator is green d The battery charge Indicator lights red 1 4 Design and operation of the voice recorder Outlook of the voice recorder SOROKA 06E is shown in Figure 2 Fig 2 The outlook of the voice recorder SOROKA 06E 2 Usage and setting up the voice recorder 2 1 Operating limitations To avoid the voice recorder failure obser...

Page 7: ...dicator Charge will turn green The charging time of a fully discharged battery is approximately 2 3 hours Attention If you want to keep the recorder for storage for over than 1 month completely charge 2 3 Charging the external accumulator Connect the supplied charger to the accumulator and then plug it into the mains supply 220V If the accumulator is discharged the indicator on the charger will li...

Page 8: ...le 3 To switch off the recorder press the control button and hold it down till the mode indicator stops flashing and goes out indicator must either begin to turn solid green or goes off Moreover if the operation has been set for the alarm clock the operation of all alarms is canceled After switching off the voice recorder remove the memory card from it and insert it into a card reader To decode th...

Page 9: ...r 15 seconds the voice recorder stops recording and goes into standby mode of the sound Closing of the current file does not happen Fragments of the audio recording in VOX mode are sequentially written to the current file up to 70 fragments in one file For each voice activation response file will be generated with label indicating the date and time of response acoustic start Fragment starting poin...

Page 10: ...ically align the level of by writes of an audio signal e Setting of the fixed gain level of the sound If the user or the program itself turned off automatic adjustment of the recording level you must specify strengthening out of existing series Recommended values are 0 dB 6 dB and 12 dB f Specify the size of the recorded files In this window the user must select the size of the files being recorde...

Page 11: ...n comparison with recording mode in format 16 bit uncompressed i Turn on off logger of the voice recorder When logger of the voice recorder is switched on all the main events will be recorded in the internal memory of the voice recorder as well as their time and date Besides in logger stores data on manufacturing of the voice recorder identification number and internal software number When you tur...

Page 12: ...larms operate in a strict sequence from the first to the tenth The voice recorder will turn itself off after the run for the last alarm l Save the configuration file After setting the desired configuration of the voice recorder click the Save configuration file The program will create a new one or overwrite an existing configuration file dict ini to the directory Copy the created file dict ini to ...

Page 13: ... cases 1 Always at the beginning and at the end of the audio recording for each file 2 When you press the control button of voice recorder for the purpose of marking the de sired recording place 3 In the voice activation mode every time of detection of sound signal voice activation The analysis of tags may be performed for example by using the program Sound Forge 6 0 and above or using the supplie...

Page 14: ...5 28 Volt Voltage on the output of power cable supply is 5 V The power cable is protected against reverse polarity voltage The power supply cord labeled in colors red or blue is positive 4 2 External accumulator As an external accumulator it is used Li Pol accumulator with an output voltage 3 3 4 2 Volt Fig 7 Example of the voice recorder SOROKA 06E operation with an external accumula tor and exte...

Page 15: ...EVICE_NUMBER Identification number of voice recorder DICT_SOFTWARE_NUMBER Number of domestic software of voice recorder POWER_RESET Reset by power failure PIN_76_RESET Processor hardware reset PMMSWBOR For official purposes WAKE_UP_FROM_LPX 5 For official purposes SECURITY_VIOLATION For official purposes SVSL For official purposes SVSH For official purposes SVML_OVP For official purposes SVMH_OVP ...

Page 16: ...rder is detected repair works are needed Current repairs of the voice recorder should be made at the factory or in the workshop Attention Unauthorised opening of the voice recorder leads to the removal of the war ranty from the voice recorder Typical faults Typical faults of the voice recorder which may be eliminated in the operating organiza tions are shown in Table 7 Table 7 Typical faults of th...

Page 17: ...s providing that the customer obeys instructions for operating conditions transpor tation and storage set up by this manual The warranty period is 12 months within the warranty period of storage The warranty period of storage is 18 months from the date of production if the charge discharge cycles of the battery are held every 3 months The warranty period is extended for the period of warranty repa...

Reviews: