MHP Operating & Maintenance Manual
9
INSTALLATION
HYDRAULIC INSTALLATION
Note: Refer to “MHP Hydraulic Schematic” on page 21.
• DO NOT
install hydraulic lines while they are pressurized.
Escaping fluid under pressure can penetrate the skin,
causing serious injury.
Hydraulic Circuit Requirements
Model
Cylinder Circuit
Connection
MHP 200
40-65 GPM (150-250 LPM)
4500-5500 PSI (310-380 Bar)
1” Code 62 Flange
MHP 350
50-110 GPM (190-416 LPM)
4500-5500 PSI (310-380 Bar)
1” Code 62 Flange
1.
Connect hydraulic hoses from the base machine to the connections on MHP (Figure 12).
Note: Remember to cap all hydraulic hoses and fittings immediately to prevent contamination of the oil.
2.
Check for any hydraulic oil leaks or interference.
CYLINDER CIRCUIT
(1 ON EACH SIDE)
HYDRAULIC CONNECTIONS
Figure 12