NORMAL OPERATION

 

After  the  unit  is  properly  installed  and  power  is  applied,  it  will  take  some  time  before  the 
system  is  cooled  down  to  temperature  and  cycling  normally.  You  should  wait  8  hours  on  the 
first startup before beginning to add product to the unit. This ensures that the unit is installed 
and operating properly before being put into service. On subsequent startups (after cleanings, 
for example), this  wait time  can be  reduced  to about  3  hours.     After  this  wait time,  the unit 
should  be  cycling  in  the  desired  temperature  band.  The  temperature  control  was  calibrated 
before leaving the factory, so no adjustment should be necessary.  

Loading the units will again cause temperature to rise as the warmer product is introduced into 
the compartment. If a large amount of product is to be introduced, it is a good idea to do it in 
stages,  allowing  several  hours  between  stages  to  allow  temperature  to  stabilize  again  before 
introducing  additional  warm  product.  This  will  minimize  the  temperature  transient  while 
loading. Other tips for successful loading include:  

-

 

Leave about 2-3 inches of free space along the back and sides of the unit to allow for proper 
air flow and, therefore, more even cooling of the product.  

-

 

Do not overload the unit. Maximum suggested load is about 75% of the chamber capacity. 
Additionally, the load should be distributed evenly from top to bottom and side to side for 
best results.  

-

 

Minimize the time the door is open. On top of letting the cold air out, you are also letting 
warm, moist air in which can result in more condensation and/or frost in the unit.   

Remember  that  the  units  are  calibrated  to  the  desired  temperature  band  before  leaving  the 
factory. We also do extensive testing to ensure that these temperatures will result in product 
temperatures in the desired band. There should be no need to adjust the temperature control 
on these units, but if it is necessary, they can be adjusted using the manual thermostat on the 
inside of the unit

.  

It  is  STRONGLY  RECOMMENDED  that  you  contact  the  manufacturer’s  Technical  Support 
Department  prior  to  performing  any  temperature  adjustments  to  ensure  the  adjustment  is 
necessary and, if so, it is performed correctly.

  

 

 

Summary of Contents for LABH-2-FM

Page 1: ...signed copy Send a written request for an inspection to the carrier B Concealed Damage This type of damage may not be discovered until the unit is being unpacked When concealed damage is discovered st...

Page 2: ...t s model and serial number ready as well as the problem description The model and serial number is located on the serial tag which can be found on the interior left upper wall of the unit For conveni...

Page 3: ...knowledging the damage This has to happen at the time of delivery or it won t happen at all Keep a copy for your records and send another to the carrier s damage claims department along with a formal...

Page 4: ...is recommended on this unit POWER SOURCE The supply circuit to this cabinet must conform to all National and Local Electrical Codes Consult the cabinet Serial Data plate for voltage cycle phase and am...

Page 5: ...rload protector The motor compressor will cycle normally as soon as the excess heat has been removed TEMPERATURE CONTROL NOTE The control is preset at the factory to provide the desired air and produc...

Page 6: ...ure transient while loading Other tips for successful loading include Leave about 2 3 inches of free space along the back and sides of the unit to allow for proper air flow and therefore more even coo...

Page 7: ...ount of stored product is overloaded Product replacements are pushed against rear wall or interrupted the proper refrigerator air circulation For the proper air circulation place the products evenly o...

Page 8: ...left upper wall of the unit PROBLEM POSSIBLE CAUSE SOULTIONS Compressor noises Compressor may be overheated Please check the room temp and ensure the range is within 65 F to 85 F If the problem still...

Page 9: ...d their seating surfaces with a clean soft cloth Shelves Soap and water Do not wash removable shelves in dishwasher Exterior and Handles Soap and water Non Abrasive Glass Cleaner Do not use commercial...

Page 10: ...e customer ADDITIONAL THREE YEAR COMPRESSOR WARRANTY In addition to the two 2 year warranty stated above Horizon Scientific Inc warrants its hermetically and semi hermetically sealed compressors to be...

Page 11: ...ing transit or installation fire flood or other external causes It does not apply to defects resulting from failure to properly install operate or maintain the product in accordance with the printed i...

Reviews: