FIGURE #1.110
Less that 1/8”
gap here
BODY HOIST INSPECTION
PROCEDURE
7.
Check the gland on each stage of
the cylinder.
8.
If the gap between the gland and
the tube is higher than 1/8 inch:
You must call Labrie Equipment’s
Service & Warranty Department
immediately at 1-877-4LABRIE.
9.
In the event that the gap between
the tube and the gland is bigger
than 1 inch:
You must stop using the vehicle
immediately and repair the
cylinder. Refer to section 1.16.2
“Body hoist replacement”.
10. Make sure that the gland safety
pins are in place.
11. When the inspection is completed,
retract the safety prop and lower
the body.
1.16.1
BODY HOIST INSPECTION (cont’d)
DANGER
INSPECTION OF THE CYLINDER
GLAND EVERY WEEK IS
MANDATORY. UNSCREWED
GLAND FROM THE BODY HOIST
WILL CAUSE THE SEPARATION OF
THE HYDRAULIC CYLINDER AND A
SUDDEN DROP OF THE BODY.
THIS TYPE OF ACCIDENT CAN
LEAD TO SERIOUS INJURIES AND/
OR IMPORTANT DAMAGES OR
EVEN DEATH.
FIGURE #1.111
Safety pin