1-89
GENERAL MAINTENANCE
The rollers of the grabber trolley are
equipped with wear pads. When the gap
between both wear pads and the guide
totals ¼ inch or more, they have to be
replaced. For example: if there’s a
0,125-inch gap between the right wear pad
and the guide and there’s a 0,125-inch gap
between the left wear pad and the guide,
the total gap is 0,250 or ¼ inch. In this
case, the wear pads MUST be replaced.To
do so, perform the following procedure.
ROLLER WEAR
PAD
GRABBER TROLLEY WEAR PADS
REPLACEMENT PROCEDURE
1.
Support the right-hand side of the
grabber first to prevent the grabber
from falling.
2.
Remove the bolts that retain the
roller support plate.
3.
Unscrew the wear pad screws and
replace it.
4.
Reinstall the plate and the bolts.
5.
Repeat the procedure for the left-
hand side of the grabber.
ROLLER SUPPORT
PLATE
BOLTS