93
Expert(t) 2000
TM
Maintenance Manual
6.
Disengage the pump;
7.
Stop the engine;
8.
Clean around the filler cap and
remove it.
9.
Use a clean container with a
minimum capacity of 60 US
gallons to collect the oil;
10.
To drop the oil, remove the drain
plug under the tank.
11.
Completely drain the tank;
12.
Once the system emptied,
reinstall the drain plug, ;
13.
Remove and clean the strainer
(once a year);
14.
Change the return filter element
(twice a year);
15.
Open the access cover. (Refer to
"Figure 145. Hydraulic tank" on
page 93 for details.)
16.
and clean the inside of the tank
of any metal particles or debris
that may have accumulated at
the bottom;
Figure 145. Hydraulic tank
17.
Refill the tank until oil reaches
3/4 of the oil gauge (Figure
1.83).
Note:Use a high quality oil, that has
good performance in cold
weather (if applicable), such
as Shell Tellus T32 or
equivalent (refer to
“Lubrication” on page 123)
The whole system will require
between 50 and 60 gallons;
CAUTION
S
OME
HYDRAULIC
TANKS
ARE
PRESSURIZED
(3
TO
5 PSI). U
NSCREW
THE
FILLER
CAP
SLOWLY
.
Strainer
Filler/
Breather Cap
Drain Plug
Access
Cover
Summary of Contents for expert 2000
Page 1: ......
Page 2: ......
Page 3: ...MAINTENANCE MANUAL 12 14 2006 Part 55379 ...
Page 4: ......
Page 10: ...viii Table of Contents ...
Page 96: ...86 CHAPTER 3 Maintenance Figure 141 Proximity switch front view ...
Page 118: ...108 CHAPTER 3 Maintenance Figure 170 Ball valve in closed position ...
Page 140: ...130 CHAPTER 4 Lubrication PACKER ...
Page 141: ...131 Expert t 2000TM Maintenance Manual BODY CHASSIS HINGES ...
Page 142: ...132 CHAPTER 4 Lubrication HOPPER SECTION STANDARD VERSION ...
Page 143: ...133 Expert t 2000TM Maintenance Manual CRUSHER PANEL ...
Page 144: ...134 CHAPTER 4 Lubrication FULL WIDTH TAILGATE ...
Page 154: ...144 CHAPTER 5 Troubleshooting ...
Page 156: ...146 Appendix CONNECTORS Commonly used Electrical Connectors Deutsch AMP ...
Page 168: ...158 Appendix ...
Page 170: ...160 Appendix ...
Page 171: ......
Page 172: ......