168
General Maintenance
2.
Fully extend the packer, then push the red emergency
STOP
button to maintain the packer in its
fully extended position.
3.
Turn OFF the hydraulic pump and the engine.
4.
Lock out and tag out the vehicle (see
Locking Out and Tagging Out the Vehicle
5.
Remove the anti-spill guards located on each side of the hopper (see Figure 3
238).
An R-pin located just behind the anti-spill guard (see Figure 3
181) must be pulled completely to
allow for the removal of the guard.
Figure 3
-
238 Anti-spill guards
6.
Open both floating panels (see Figure 3
239).
Floating panel can be open by pulling down the locking pin and by pulling on the handle.
N
OTE
:
The locking pin must be kept down when pulling on the handle.
Danger!
Do not enter the hopper while the packer is moving.