General Maintenance
187
10.
Fully extend the packer, then push the red emergency
STOP
button to maintain the packer in its
fully extended position.
11.
Turn OFF the hydraulic pump and the engine.
12.
Lock out and tag out the vehicle (see
Locking Out and Tagging Out the Vehicle
13.
Remove the deflector panel on the automated arm assembly (see Figure 3
271).
Use a ¾-inch wrench to remove the 4 lower bolts that hold the panel.
Also remove the 3 carriage bolts located at the center of the automated arm assembly (see Figure
271).
In order to access these bolts and remove them, lift the arm cover open.
Figure 3
-
271 Deflector panel
14.
Remove the transversal beam by taking out the 4 bolts (2 on each side) that retain it.
Figure 3
-
272 Transversal beam
Danger!
Do not enter the hopper while the packer is moving.
Remove these 3
carriage bolts
Deflector panel
Arm cover