General Maintenance
37
13.
Finish cleaning the area with pressurized water.
14.
Perform a visual inspection of the area behind the packer through the clean-out traps. Check for
possible leaks in the hydraulic system and wear signs on mechanical parts such as: rollers,
cylinder pins, hoses, pipes,, connections, and hopper floor and sidewalls. Also check cylinders
and hoses for leaks as well as bolts for proper tightness.
15.
Climb inside the hopper using a small step-ladder.
16.
Fully open both floating panels (see Figure 3
12).
To open panel just pull down the sliding button next to the handle and keep it down while pulling
the panel towards you. Tilt it until completely open (see Figure 3
13).
Figure 3
-
12 Floating panels
Figure 3
-
13 Floating panel completely open
17.
Remove all accumulated dirt on the follower panels using the provided hoe or pressurized water.
18.
Once cleaning is complete, close both floating panels.