I N STALLER’S M AN UAL
A
ppliances must be installed in a workmanlike manner in accordance with the instructions in
this manual and locally applicable regulations. This manual will be handed over to the user after
installation.
Before connection, check that the
Mains voltage is compatible with the appliance’s rated voltage and thermal output.
Connection :
- Use a 3-wire grounded cord rated for 13 A or 4-wire rated for 30 A 125 / 250 VAC, type SRD,
SRDT, S, SO or ST.
- Where local Codes do not permit grounding through neutral, use a 4-wire power supply cord or
«pigtail» kit. Cord must be agency approved for use with household ranges.
-
R
emove cover ( or covers)
A
/ figure
1
, to the back of the unit identified by
.
-
U
se a standard flexible cable to connect to terminal block
B
/ figures
1
&
2
.
-
S
ecure the cable by means of cable clamp
C
/ figure
2
, depending on your power supply figures
1
&
2
.
- Refit access door.
It is hazardous to put the appliance into service without connecting it to suitable ground.
ELECTRIC CONNECTION
No liability can be accepted for accidents resulting from non-compliance with this
requirement or incorrect grounding.
L
N
1
2
400 V 3N ~ 50 Hz
230 V 1N ~ 50 Hz
230 V 1N ~ 50 Hz
230 V 3 ~ 50 Hz
L1
N
L2 L3
1
2
3
4
5
N
L1
L2
L3
L
1
2
3
4
5
1
2
3
4
5
The supply of three phase 400 without neutral is not possible
1
A
C
B
D
2