INSTALLER’S MANUAL
Comissioning (fine tuning) Oven Burner :
Ź
Ignite the oven to Gas Mark 10. Wait for 15 minutes to reach temperature and then reduce to
minimum setting, and remove the control knob (see
M
, figure
14
).
Ź
8VLQJDÀDWKHDGVFUHZGULYHUDGMXVWWKHVLPPHUÀDPHDFFRUGLQJO\VHH
M
, figure
14
). The hole
allowing access for the screwdriver is located behind Gas Mark 7.
Note
7KHÀDPHLVUHGXFHGWRóZKHQ\RXWXUQPD[LPXPWRPLQLPXP/RRNLQJIRUDFULVSEOXH
ÀDPHZLWKRXWDQ\\HOORZZKLFKGRHVQRWJRRXWZKHQWXUQHGIURPPD[LPXPWRPLQLPXP
Setting the safety thermocouple (Oven) :
If the burner goes out, having kept the control knob pushed in for approximately twenty seconds,
check that:
7KHPDJQHWLFKHDGJULSVWKHYDOYHPRGHUDWHO\¿QJHUULJKW
- The tip of thermocouple (see
N
, figure
15
)
VKRXOGEHWRXFKHGE\WKHÀDPHZLWKRXWFRPLQJLQWR
contact with the burner.
- The thermocouples and magnetic heads are absolutely clean.
/RRNLQJIRUDFULVSEOXHÀDPHZLWKRXWDQ\\HOORZZKLFKGRHVQRWJRRXWZKHQWXUQHGIURPPD[L
-
mum to minimum.
CHANGING GAS TYPE
3 mm
14
M
15
N
Adjusting the primary air :
!$GMXVWWKHDLUÀRZE\PRYLQJWKHDGMXVWLQJDLUULQJ
figure
12
), table n°
7
appendix
0.
> Replace base plate and drawer (figure
13
).
12
13
Adjusting air ring
CAUTION :
After connection or changing gas type, it is imperative to adjust for
D¿QHWXQLQJ