INSTALLER’S MANUAL
CLUNY
Page 13 of 42– US –
Unscrew the screws
C
near the burner openings (Figures 6 and 7). Pull and raise the top after having loosened the 2
screws
D
(Fig. 8, CHAGNY and 9, CHAGNY 1400-1800), wedge the cooking surface.
A pressure regulator (fig. 10) is located in the right rear corner under the hob, to gain access to the pressure regulator,
remove the top.
Convertible regulator
The reversible cap is labeled either « LP » or « Nat » and is easily recognized by the raised center screw slot (for
natural) or the center depth (for LP).
To change LP to Natural or vice versa, the seal screw in the regulator lid is unscrewed, reversed and reinstalled to
convert from one setting to another (Figure 12).
Fig. 10
Fig. 11
LP Setting
Fig. 12
Figure 7
C
C
Fig. 8
Fig. 9
D
Nat Setting