INSTALLER’S MANUAL
CLUNY
Page 16 of 42– US –
Fig. 21
Oven orifice:
Remove the base,
CAUTION:
when refitting place the base underneath the groove on the fascia (Figures 18 and 19).
Remove the oven burner.
Disconnect the connection piece, unscrew screw
M
on the orifice
holder (Figure 22). Replace the orifice (Table
5
).
Pilot burner orifice:
Change the pilot burner orifice
Gas pilot LP: 65103032
Gas pilot NG: 65103031
Adjustment of oven primary airflow:
Remove the base, unscrew the screw
K
holding the burner (Fig.20).
Adjust the air ring (Table 6, Figure 23).
Table 6
Opening in mm / inches
GAS
Pressure
Oven
Natural Gas
6" WC
4 /
3
/
16
L.P. propane
10" WC
6 /
1
/
4
Adjusting pilot burner air supply
Turn ring
P
to fully open for Butane/Propane, to half open for natural gas (Figures 24)
Table 5
Ø
GAS
Pressure
Gas oven
Pilot burner
Natural gas
6" WC
1.40
0.45
L.P. propane
10" WC
0.95
0.25
Fig. 19
Fig. 18
Fig. 20
K
Fig. 23
Air Adjustment
Fig. 24
P
Fig. 22
L