INSTALLER’S MANUAL
CORMATIN
Page 10 of 40
Table 3
Burners SF
F
I
UF
GAS
Pressure
Ø
Natural gas
6" WC
0.90 1.30 1.45
1.70
L.P. propane
10" WC
0.65
0.90 1.05
1.20
Adjustment of reduced flowrate of surface burners
(Figure 18) :
After connection or change of gas, it is
crucial
to modify this
adjustment.
- Remove the control knob. Light the burner, adjust to
minimum setting, and then use a small screwdriver to set the
adjusting screw
J
.
Note
: Flame is reduced to ¼ of its size in the minimum setting,
the burner must remain lit when changing from maximum
setting to minimum setting.
Refitting the cooking surface :
When refitting the cooking surface, it is vital to tighten
fastening screws (figures 7, 8 and 9). Failure to do so can cause distortion of the cooking surface.
OVEN BURNERS :
Oven orifice :
Remove the base,
CAUTION:
when
refitting place the base underneath the groove on the fascia
(Figures 19 and 20).
Disconnect the connection piece; unscrew screw
K
on the orifice holder (Figure 21). Replace the orifice (Table 5).
Table 5
Ø
GAS
Pressure
Oven
Natural gas
6" WC
1.40
L.P. propane
10" WC
0.95
Fig. 18
J
Fig. 20
Fig. 19
Table 4
Burners SF
F
I
UF
GAS
Pressure
Opening in mm/ inches
Natural gas
6" WC
2.5 /
3
/
32
2.5
/
3
/
32
max
7 /
1
/
4
L.P. propane
10" WC 3.5 /
9
/
64
6
/
15
/
64
max max