INSTALLER’S MANUAL
CORMATIN
Page 11 of 40
Adjustment of oven primary airflow :
Remove the base, loosen the screw
L
that secures the air ring and then adjust (Table 6, Figure 22).
Table 6
Opening in mm / inches
GAS
Pressure
Oven
Natural gas
6" WC
4 /
3
/
16
L.P. propane
10" WC
6 /
1
/
4
Adjustment of oven selector :
Adjustment is
VITAL
after connection or any change of gas.
When the range is installed, be sure that this selector cartridge (Fig. 23 and 24) is turned all the way to the proper setting. Turn
J
clockwise to the stop for LP Gas; counterclockwise
M
to the stop for Natural Gas.
IT IS EXTREMELY IMPORTANT THAT THIS SELECTOR CARTRIDGE IS SET FOR THE GAS ON
WHICH THE RANGE IS TO BE USED.
LP
LP
N
Natural
LP
N
Off
Fig. 24
Fig. 21
K
Fig. 22
L
Fig. 23
M