INSTALLER’S MANUAL
CORMATIN
Page 13 of 40
BACK SPACER VENT FITTING :
It is
MANDATORY
to mount the back spacer vent
R
supplied with the
appliance (or equivalent) to the wall, this allows for ventilation and
reduces the risk of heat damage.
Screw the 2 brackets
S
to the wall according to figures 30, 31 and 32
(screws not supplied), then fit the back spacer vent onto these brackets by using the washers and nuts supplied with the
range.
STABILITY DEVICE INSTALLATION INSTRUCTIONS :
Screw the anti-tip bracket
T
to the wall according to figures 30, 31, 32 and 33 (screws not supplied).
Remove the drawer; push the range against the wall until the anti-tip bracket screw goes through the back of the range.
Through the drawer gap, screw the nut and its washer on the anti-tip bracket screw.
1
1
2
2
3
4
5
L1
N
120/240 V ; 3-Pole ; 4-wire
L2
Fig. 29
Figure 31
70 mm
2
3
/
4
’’
T
S
R
Figure 30
Fig. 28
Q
Fig. 27
P