It is hazardous to put the appliance into service without connecting it to suitable ground.
No liability can be accepted for accidents resulting from non-compliance with this requirement or incorrect grounding.
Connect the equipotential bonding terminal (
N
, Figure 30).
Before connection, check that the
:
Mains voltage is compatible with the appliance’s rated voltage and thermal output.
Connection:
-
Use a 4-wire cord rated for 30 A 125 / 250 VAC, type SRD, SRDT, S, SO or ST.
-
Where local Codes do not permit grounding through neutral, use a 4-wire power supply cord or “pigtail” kit. Cord
must be agency approved for use with household ranges.
-
Remove access door
O
(Figure.31).
-
Remove cable clamp and loosen supply cord mounting screws on the terminal block.
-
Connect to terminal block in accordance with figure 34.
-
Secure the cable by means of cable clamp
(no provided), item
Q
(Figure 33).
-
Refit access door
BACK SPACER VENT
FITTING:
It is mandatory to mount the back spacer vent
R
to the wall supplied with the appliance.
Screw the 2 brackets
S
to the wall according to figures 35, 36 and 37 (screws not supplied), then fit the back spacer
vent onto these brackets by using the washers and nuts supplied with the range.
STABILITY DEVICE INSTALLATION INSTRUCTIONS:
Screw the anti-tip bracket
T
to the wall according to figures 36 and 37 (screws not supplied).
Remove the right-hand drawer, push the range against the wall until the anti-tip bracket screw goes through the back of
the range. Through the drawer gap, screw the nut and its washer on the anti-tip bracket screw
N
Fig. 30
R
S
O
Fig 31
Fig. 32
M
Q
Fig. 33
Fig. 34
Page 15 of 38 – US –
Summary of Contents for Fourneau "Rully"
Page 2: ...Page 2 of 38 US ...
Page 8: ...Page 8 of 38 US ...
Page 19: ...Détail A Détail B 65 103032 LP 65 103031 NG 65 103029 65 103033 65 103033 Page 19 of 38 US ...
Page 22: ...Page 22 of 38 US ...
Page 24: ...Page 24 of 38 US ...