Adjustment of reduced flowrate of surface burners (Figure 23):
After connection or change of gas, it is
crucial
to modify this
adjustment.
- Remove the control knob. Light the burner, adjust to
minimum setting, then use a small screwdriver to set the
adjusting screw
J
.
Note:
Flame is reduced to ¼ of its size in the minimum
setting, the burner must remain lit when changing from
maximum setting to minimum setting.
Refitting the cooking surface:
When refitting the cooking surface, it is vital to tighten
fastening screws (figures 4, 5 and 6). Failure to do so can
cause distortion of the cooking surface.
OVEN BURNERS:
Disassembling of the gas oven burner:
Withdraw the plate (Fig.15).
CAUTION:
when refitting, place the base front underneath the groove on the fascia (fig.16).
Unscrew screw
K
holding the burner (Fig.17).
Remove the drawer.
Unscrew the two flathead screws
L
(Fig.17). Remove screen under gas oven.
Unscrew screw
M
on the orifice holder (Figure 19).
Push the burner towards the back of the oven cavity and to raise it to release it.