LaCie 12big Rack Network
Troubleshooting & Problem Solving
User Manual
page 26
4.1. Overview
The LaCie 12big Rack Network Enclosure includes an Enclosure
Services Processor and associated monitoring and control logic to
enable it to diagnose problems within the Enclosure Management
Card, Ops Panel, CPU(s) and DIMM(s).
The sensors for power and cooling conditions are housed within the
Power Supply and Cooling Fans. There is independent monitoring
for each unit.
4.1.1. Initial Start-up Problems
4.1.1.1. Faulty Cords
First check that you have wired up the subsystem correctly. Then, if:
✦
cords are missing or damaged
✦
plugs are incorrect
✦
cords are too short
Call your supplier for a replacement.
4.1.1.2. Alarm Sounds On Power Up
Please refer to
4.3. Audible Alarm
.
4.1.1.3. Computer Doesn’t Recognize the LaCie
12big Rack Network Subsystem
1. Check that the interface cables from the LaCie 12big Rack Net-
work enclosure to the host computer are fitted correctly.
2. Check that the LEDs on all installed drive carrier modules are
illuminated (Amber). Note that the drive LEDs will not be lit dur-
ing drive spinup.
3. Check that Drive Carrier Modules have been correctly installed.
4. Troubleshooting & Problem Solving