LaCie 12big Rack Network
Troubleshooting & Problem Solving
User Manual
page 31
LED/Buzzer
State
Related
Meaning
Action
Constant On
Constant – no fan lights
lit constant
Failure State – tem-
perature in range where
damage could occur
Check ambient tempera-
ture and increase if too
cold or decrease if too
hot immediately. If this
does not work check for
fan failure that has a
broken light too.
Constant – multiple fan
lights lit constant
Fans broken or out of
tolerance
Replace Fans immedi-
ately. Decrease ambient
temperature
Fan Light
Constant On
Varying levels of beep
and chassis fault light
setting. No beep if
muted.
Fan broken or out of
tolerance
Replace Fans immedi-
ately.
Flashing
Fan Ident On
--
Drive Light (amber)
Constant On
Varying levels of beep
and chassis fault – usu-
ally slow beep and slow
flash. No beep if muted.
Drive faulty
Replace drive
Flashing
Drive Ident On
--
Ops Panel Ident LED
Flashing
Ops Panel Ident On
--
Buzzer
Off
Ops Panel Fault LED Off
No issues
Smile
Off
Ops Panel Fault LED
Flashing or Constant
Muted.
See Ops Panel LED set-
tings above for inter-
pretation of lights and
remedy.
Intermittent short beep
(0.5 second beep every
32 seconds)
Various Ops Panel Fault
light flash states
Fault has occurred and
system is muted but in
remind mode
Check fault status using
Ops Panel fault LED set-
tings and remedy.
Slow beep (half second
beep every 8 seconds).
Ops Panel Fault LED
slow blink (0.5 seconds
On, 3.5 seconds Off).
Warning Mode
See Ops Panel fault LED
settings above
Faster beep (1.5 sec-
onds beep, 0.5 second
silence).
Ops Panel Fault LED fast
blink (alternating every
half second
Critical Mode
See chassis fault LED
settings above
Constant beep
Ops Panel Fault LED
constant On
Failure Mode
See Ops Panel fault LED
settings above