LaCie 12big Rack Network
Technical Specifications
User Manual
page 48
Shock, Non-Operational
20g 10ms 1/2 sine (test w drives)
30g 10ms 1/2 sine (test w/o drives)
Vibration, Operational
0.2grms 5-500 Hz Random
Vibration, Non-Operational
0.8grms 2-200 Hz Random (test w drives)
1.04grms 2-200 Hz Random (test w/o drives)
Vibration, Relocation
0.15g 2-200 Hz sine (test w drives)
0.3g 2-200 Hz sine (test w/o drives)
Acoustics
Sound Power Operating: All fans running at 46%: Less than 58 dB LpA average measured at the by-
stander positions.
(The 4 bystander positions are 1m horizontal and 1.5m off the floor positioned front, back, left and right.
The unit under test will be measured on the floor). Measured at 20°C
Orientation & Mounting
19” Rack mount (2EIA Units)
Rack Rails
To fit 800mm depth racks compliant with IEC 297
Rack Characteristics
Back pressure not exceeding 5 pascals (0.5mm water gauge)
6.4. AC Power Module (2 x 850W PSU)
Voltage Range
100-240V AC Rated
Voltage Range Selection
Full Range PSU
Frequency
50/60 Hz
Input Current
12 A
Power Factor Correction
95%@110V full load
Harmonics
Meets EN61000-3-2
Output
+5 V aux: 4A, +12 V: 70A
max
Output Rails
6
Dimensions
84mm high x 107mm wide x
371mm Long (3.3in x 4.21in
x 1.46in)