3.4. Employing the
Advance
model
3.4.1. Startup of the
Advance
model
(See image 3)
Before starting the connection, always be sure that the coupling nut (7) has an O-ring (6)
inside. If there is not one there, put one in.
Once this has been verified, connect the coupling nut (7) to the threaded CO2 bottle (2).
Do not use a wrench to tighten the coupling nut (7); only tighten by hand.
If the con-
nection is not possible to make correctly, do not continue the operational startup procedure,
contact the CO2 bottle supplier and use another one.
Connect the metal hose safety cable (5) to the bottle shutoff valve (1).
Connect the
LACOR
model network cable to the 220V electricity network.
Verify that the network cable is also connected to the
LACOR
equipment.
If the model has a power switch, press it; if it does not have one, it will turn on automatica-
lly when connected to the electricity network.
Verify that the petcock (8) is closed and next, open the bottle shutoff valve, (1) turning it
to the right.
3.4.2. Use of the
Advance
model
(See Section 4.2.)
Press the Power Switch
(image 2, nº 6)
to turn on the equipment.
Select cycle:
ECO.
Economical consumption cycle, approximate temperature of -10°C.
MIN.
Minimum consumption cycle, approximate temperature of -15°C.
MED.
Medium consumption cycle, approximate temperature of -20°C.
MAX.
Maximum consumption cycle, approximate temperature of -30°C.
The program that has been selected will appear on-screen.
To select a different cycle, press the corresponding button.
Summary of Contents for ICE
Page 1: ...ES EN DE FR PT MANUAL DE INSTRUCCIONES ICE ADVANCE...
Page 2: ......
Page 16: ......
Page 17: ...ES EN DE FR PT EN INSTRUCTION MANUAL ICE ADVANCE...
Page 18: ......
Page 32: ......
Page 33: ...ES EN FR PT DE HANDBUCH ICE ADVANCE...
Page 34: ......
Page 48: ......
Page 49: ...FR ES EN PT DE MANUEL DE INSTRUCCIONES ICE ADVANCE...
Page 50: ......
Page 64: ......
Page 65: ...ES EN DE PT FR MANUAL DE INSTRU ES ICE ADVANCE...
Page 66: ......