background image

OUT/+ key  

 

Press shortly to toggle between 

MAX/MIN

 and current outdoor temperature/humidity data 

 

Increase, change, toggle all values in manual set mode

 

Moon phase icon 

Weather tendency 
indicator

 

Time

 

Calendar or alarm time 

Indoor relative 
humidity in RH%

 

Time reception icon 
(for DCF time) 

Indoor temperature 
in ºC/ ºF

 

Weather forecast icon

 

Outdoor data signal 
reception indicator

Outdoor temperature 
in ºC/ ºF 

 

Outdoor relative 
humidity in RH%

 

Comfort indicator icon

 

Relative air pressure 
history bar graph 

Relative air pressure 
in hPa / inHg 

 

Press to set the alarm minute (inside alarm setting mode) 

 

Stop the alarm during alarm ringing 

 

Stop snooze mode 

 Back-light 

on 

 

SNOOZE/CH key  

 Active 

snooze 

function 

during alarm ringing

 

it 

the 

manual set mode and alarm setting mode

 

 Ex

 

Switch among display of channels (if more than 1 transmitter is used)

 

 Back-light 

on

 

  

LCD SCREEN  

The LCD screen is split into 

sections displaying the information for time/calendar/alarm/moon 

phase, indoor data, weather forecast and outdoor data. 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 
 

 
 
 
 
 

 

 
 
MANUAL SETTINGS: 

The following manual settings can be changed when pressing the SET key for: 

 

LCD contrast setting 

 Time 

zone 

setting 

 

Time reception ON/OFF setting 

 

12/24-hour format setting 

 

Manual time setting 

 Calendar 

setting 

 

°C/°F temperature setting 

 

hPa / inHg pressure setting

 

 

Relative air pressure setting

 

 

Weather forecasting icon sensitivity setting 

 

LCD CONTRAST SETTING: 
 
 
 
 

 

The LCD contrast can be set within 8 levels, from LCD 0 to LCD7 (Default setting is 

LCD 

4): 

1. 

Press and hold the SET key until the digit starts flashing. 

2. Use 

the 

OUT/+

 key to view all levels of contrast.  

3. 

Select the desired LCD contrast. Confirm with the SET key and enter in the 

Time Zone 

setting

 

TIME ZONE SETTING: 

 

 

 

Flashing 

 

The time zone default of the Weather Station is “0”. To set a different time zone: 
1. 

The current time zone value starts flashing.  

2. Use 

the 

OUT/+

 key to set the time zone. The range runs from 0 to -12 and then runs from +12 

back to 0 in consecutive 1-hour intervals. 

3. 

Confirm with the SET key and enter the

 Time reception ON/OFF setting

 

TIME RECEPTION ON/OFF SETTING: 

 

 
 
 
 
 

In area where reception of the DCF time is not possible, the DCF time reception function can be 
turn OFF. The clock will then work as a normal Quartz clock. (Default setting is ON). 
1. 

The digit “ON” will start flashing on the LCD.  

2. Use 

the 

OUT/+

 key to turn OFF the time reception function. 

3. 

Confirm with the SET key and enter the 

12/24-hour format setting

 

Note: 
If the Time Reception function is turn OFF manually, the clock will not attempt any reception 
of the DCF time as long as the Time Reception OFF function is activated.  

The time reception icon and the “DCF” icon will not be displayed on the LCD. 

 

12/24-HOUR FORMAT SETTING: 
 
 
 

 

 

 

The hour display can be selected to show hours in 12-hour or 24-hour settings. (Default 24-Hour) 
1. Use 

the 

OUT/+

 key to toggle between “12H” or “24H”. 

2. 

Confirm with the SET key and enter the 

Manual time setting

Flashing 

Flashing 

Last digit flashing 

 

Summary of Contents for WS9032

Page 1: ...to weather station by 433 MHz signals LCD showing outdoor temperature and humidity Wall mounting case TO INSTALL AND REPLACE BATTERIES IN THE WEATHER STATION The Weather Station uses 3 x AA IEC LR6 1 5V batteries To install and replace the batteries please follow the steps below Hanging hole 1 Insert finger or other solid object in the space at the bottom center of the battery compartment and lift...

Page 2: ...y occur RESETTING The Weather Station and the Thermo hygro transmitter need to be reset when one of the following conditions occur Unsuccessful 433MHz signal reception Malfunction on the units Batteries replacement For resetting remove all batteries from the units Wait at least for 1 minute before powering up the Weather station again Proceed from step 1 in Setting Up DCF RADIO CONTROLLED TIME The...

Page 3: ...CD CONTRAST SETTING The LCD contrast can be set within 8 levels from LCD 0 to LCD7 Default setting is LCD 4 1 Press and hold the SET key until the digit starts flashing 2 Use the OUT key to view all levels of contrast 3 Select the desired LCD contrast Confirm with the SET key and enter in the Time Zone setting TIME ZONE SETTING Flashing The time zone default of the Weather Station is 0 To set a di...

Page 4: ... Confirm with the SET key and enter the Air pressure unit setting hPa inHg PRESSURE UNIT SETTING The pressure display can be selected to show relative air pressure in hPa or inHg default is hPa 1 Use the OUT key to toggle between hPa or inHg unit 2 Confirm with the SET key and enter the Relative air pressure value setting Note Units of weather icon sensitivity and air pressure history are not affe...

Page 5: ... display Note The MIN or MAX data needs to be reset individually WEATHER FORECAST AND WEATHER TENDENCY WEATHER FORECASTING ICONS Weather icons in the third section of LCD can be displayed in any of the following combinations Sunny Cloudy with sunny intervals Rainy For every sudden or significant change in the air pressure the weather icons will update accordingly to represent the change in weather...

Page 6: ...s to reset the respective MIN or MAX record to current temperature and humidity data and current time date display Note The MIN or MAX data needs to be reset individually BACK LIGHT The back light is automatically switched ON when any keys are pressed The back light will be switched on for approximately 8 seconds before automatically switching OFF ABOUT THE OUTDOOR TRANSMITTER The range of the The...

Page 7: ...rn it to their original point of purchase for repair by a qualified engineer Opening and tampering with the units may invalidate their guarantee Do not expose the units to extreme and sudden temperature changes this may lead to rapid changes in forecasts and readings and thereby reduce their accuracy SPECIFICATIONS Temperature measuring range Indoor 9 9ºC to 59 9ºC with 0 1 C resolution 14 2ºF to ...

Page 8: ...ION WEATHER STATION STATION MÉTÉO WEERSTATION STAZIONE METEOROLOGICA ESTACIÓN METEOROLÓGICA Betriebsanleitung Instruction Manual Manuel d Instructions Handleiding Manuale delle istruzioni Manual de instrucciones ...

Reviews: