background image

the foldout table stand is extended, place the weather station in an appropriate 
location.

 

 

POSITIONING THE THERMO-HYGRO TRANSMITTER 

The Thermo-hygro transmitter is supplied with a holder that may be 
attached to a wall with the three screws supplied. Before securing the 
transmitter, ensure that the 433MHz signal is properly received. To attach to 
the wall, please follow the steps below: 
1. 

Mark the wall using a pen through the holes in the holder to obtain the 
exact drilling position. 

2. 

Drill holes in the wall at the points marked. 

3. 

Screw holder onto wall. 

 

There is also double sided tape included with the wall mount. On smooth surfaces this can be used 
instead of drilling holes. The mounting surface can, however, affect the transmission range. If for 
example the unit is attached to a piece of metal, it may then either reduce or increase the 
transmitting range. For this reason, we recommend not placing the unit on any metal surfaces or in 
any position where a large metal or highly polished surface is in the immediate proximity (garage 
doors, double glazing, etc.). Before securing in place, please ensure that the Weather station can 
receive the 433MHz signal from the Thermo-hygro transmitter at the positions that you wish to 
situate them.  
The Thermo-hygro transmitter simply clicks in or out of the holder. When inserting or removing the 
Thermo-hygro transmitter from the wall holder please hold both units securely. 

 

CARE AND MAINTENANCE:

 

 

Extreme temperatures, vibration and shock should be avoided as these may cause damage to 
the units and give inaccurate forecasts and readings. 

 

When cleaning the display and casings, use a soft damp cloth only. Do not use solvents or 
scouring agents as they may mark the LCD and casings. 

 

Do not submerge the units in water. 

 

Immediately remove all low powered batteries to avoid leakage and damage. Replace only 
with new batteries of the recommended type. 

 

Do not make any repair attempts to the units. Return it to their original point of purchase for 
repair by a qualified engineer. Opening and tampering with the units may invalidate their 
guarantee. 

 

Do not expose the units to extreme and sudden temperature changes, this may lead to rapid 
changes in forecasts and readings and thereby reduce their accuracy. 

 

SPECIFICATIONS: 

 

Temperature measuring range: 

Indoor 

   

  :  -9.9ºC to +59.9ºC with 0.1°C resolution  

 

 

 

 

14.2ºF to 139.8ºF with 0.2ºF resolution 

 

  

 

  

 

(“

OF.L

” displayed if outside this range)  

Outdoor 

   

  :  -29.9ºC to +69.9ºC with 0.1°C resolution 

 

 

   

  -21.8ºF to +157.8ºF with 0.2ºF resolution  

(“

OF.L

” displayed if outside this range)   

Indoor and outdoor relative humidity range: 

1% to 99% with 1% resolution  

 

  (Display “- -“ if outside this range or temperature is 

OF.L

Interior data checking intervals 
Indoor Temperature 

  :  Every 15 seconds 

Humidity  

  :  Every 20 seconds 

Air pressure checking interval    :   Every 15 seconds 

Outdoor temperature and humidity data checking interval: 

Every 5 minutes 

 

Transmission range 

  :  up to 

100

 meters (open space) 

Power consumption: 

(alkaline batteries recommended) 

Weather station 

  :  3 x AA, IEC LR6, 1.5V  

Thermo-hygro transmitter 

  : 

2 x AAA, IEC LR3, 1.5V

  

Dimensions (L x W x H): 

 

 

Weather station 

  : 

117.4 x 31.2 x 227.1mm  

Thermo-hygro transmitter 

  : 

56 x 24 x 80 mm (excluding wall bracket)

 

 

LIABILITY DISCLAIMER 

 

The manufacturer and supplier cannot accept any responsibility for any incorrect readings and 
any consequences that occur should an inaccurate reading take place. 

 

This product is not to be used for medical purposes or for public information.  

 

This product is only designed to be used in the home as indication of the future weather and is 
not 100% accurate. Weather forecasts given by this product should be taken only as an 
indication and not as being totally accurate. 

 

The specifications of this product may change without prior notice. 

 

This product is not a toy. Keep out of the reach of children. 

 

No part of this manual may be reproduced without written consent of the manufacturer. 

       

 
 

R&TTE Directive 1999/5/EC 

Summary of the Declaration of Conformity :  We hereby declare that this wireless transmission device does comply 
with the essential requirements of R&TTE Directive 1999/5/EC.

  

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

Summary of Contents for WS9032

Page 1: ...to weather station by 433 MHz signals LCD showing outdoor temperature and humidity Wall mounting case TO INSTALL AND REPLACE BATTERIES IN THE WEATHER STATION The Weather Station uses 3 x AA IEC LR6 1 5V batteries To install and replace the batteries please follow the steps below Hanging hole 1 Insert finger or other solid object in the space at the bottom center of the battery compartment and lift...

Page 2: ...y occur RESETTING The Weather Station and the Thermo hygro transmitter need to be reset when one of the following conditions occur Unsuccessful 433MHz signal reception Malfunction on the units Batteries replacement For resetting remove all batteries from the units Wait at least for 1 minute before powering up the Weather station again Proceed from step 1 in Setting Up DCF RADIO CONTROLLED TIME The...

Page 3: ...CD CONTRAST SETTING The LCD contrast can be set within 8 levels from LCD 0 to LCD7 Default setting is LCD 4 1 Press and hold the SET key until the digit starts flashing 2 Use the OUT key to view all levels of contrast 3 Select the desired LCD contrast Confirm with the SET key and enter in the Time Zone setting TIME ZONE SETTING Flashing The time zone default of the Weather Station is 0 To set a di...

Page 4: ... Confirm with the SET key and enter the Air pressure unit setting hPa inHg PRESSURE UNIT SETTING The pressure display can be selected to show relative air pressure in hPa or inHg default is hPa 1 Use the OUT key to toggle between hPa or inHg unit 2 Confirm with the SET key and enter the Relative air pressure value setting Note Units of weather icon sensitivity and air pressure history are not affe...

Page 5: ... display Note The MIN or MAX data needs to be reset individually WEATHER FORECAST AND WEATHER TENDENCY WEATHER FORECASTING ICONS Weather icons in the third section of LCD can be displayed in any of the following combinations Sunny Cloudy with sunny intervals Rainy For every sudden or significant change in the air pressure the weather icons will update accordingly to represent the change in weather...

Page 6: ...s to reset the respective MIN or MAX record to current temperature and humidity data and current time date display Note The MIN or MAX data needs to be reset individually BACK LIGHT The back light is automatically switched ON when any keys are pressed The back light will be switched on for approximately 8 seconds before automatically switching OFF ABOUT THE OUTDOOR TRANSMITTER The range of the The...

Page 7: ...rn it to their original point of purchase for repair by a qualified engineer Opening and tampering with the units may invalidate their guarantee Do not expose the units to extreme and sudden temperature changes this may lead to rapid changes in forecasts and readings and thereby reduce their accuracy SPECIFICATIONS Temperature measuring range Indoor 9 9ºC to 59 9ºC with 0 1 C resolution 14 2ºF to ...

Page 8: ...ION WEATHER STATION STATION MÉTÉO WEERSTATION STAZIONE METEOROLOGICA ESTACIÓN METEOROLÓGICA Betriebsanleitung Instruction Manual Manuel d Instructions Handleiding Manuale delle istruzioni Manual de instrucciones ...

Reviews: