PRESENTATION OF THE APPLIANCE
3
1.
PRESENTATION OF THE APPLIANCE
For optimum operation of the appliance, we advise you to read this manual carefully before
switching on the appliance for the first time. In case of problems or concerns, we urge you to
contact your dealer, who will cooperate with you.
In order to improve the product, the manufacturer reserves the right to make changes
without notice by updating this document.
This appliance is designed to burn wood in absolutely safe conditions.
WARNING
: Faulty installation may have serious consequences.
Installation and all necessary regular maintenance operations must be performed by an
authorized installer in full accordance with the specifications set out in the legislation
applicable in each country and this instruction book.
1.1.
General characteristics
Unit
CM-300
CM-300 FD
CM-300 FI
CM-300 R
Nominal Heat Output (N.H.O.) to atmosphere
kW
10.53
11
11
10.5
Efficiency at N.H.O.
%
80
79
79
74
CO emission at 13% O2 at N.H.O.
%
0.37
0.33
0.33
0.31
Gas mass flow at N.H.O.
g/s
9
10
10
11
Gas temperature of flue at N.H.O.
ºC
229
230
230
286
Optimum flue draught
Pa
12
12
12
12
Wood consumption (beech) at N.H.O.
Kg/h
2.6
2.8
2.8
2.8
Dimensions of the firebox
Width
mm
660
640
640
730
Depth
mm
410
410
410
444
Useful height
mm
390
390
390
390
Maximum length of the logs
cm
60
60
60
60
Volume heated (45w/m³) at N.H.O.
m³
233
244
244
233
Log load frequency
h
1
1
1
1
Capacity of the ashpit
L
3.2
3.2
3.2
2.6
Weight
kg
175
175
175
190
Flue socket diameter
mm
200
200
200
200
Energy efficiency class
-
A+
A+
A+
A+
Energy efficiency index (EEI)
-
107
107
107
107
Note:
The values indicated in the above table are based on tests performed in accordance
with UNE-EN 13240 with logs with no more than 18% humidity and pressure conditions as
indicated in each case.
Warning:
this appliance is designed and prepared to work with the types of fuel, degree of
humidity of the fuel, fuel loads, fuel load frequencies, flue draught and system of installation
indicated in this Instruction Book. Failure to respect these conditions may lead to problems
with the appliance (deterioration, shorter useful life, etc.) which are not covered by the
Lacunza warranty.
Summary of Contents for CM-300
Page 1: ...CM 300 CM 300 FD CM 300 FI CM 300 R Instruction Book ...
Page 19: ...DECLARATION OF PERFORMANCE 18 6 DECLARATION OF PERFORMANCE ...
Page 20: ...DECLARATION OF PERFORMANCE 19 6 ...
Page 21: ...DECLARATION OF PERFORMANCE 20 6 ...
Page 22: ...DECLARATION OF PERFORMANCE 21 6 ...
Page 23: ...CE MARK 22 7 CE MARK ...
Page 24: ...CE MARK 23 7 ...
Page 25: ...CE MARK 24 7 ...
Page 26: ......
Page 27: ......