For  optimum  operation  of  the  appliance,  we  advise  you  to  read  this  manual  carefully 

before switching on the appliance for the first time. In case of problems or concerns, we urge 
you to contact your dealer, who will cooperate with you.  

In  order  to  improve  the  product,  the  manufacturer  reserves  the  right  to  make  changes 

without notice by updating this document. 

This appliance is designed to burn wood in absolutely safe conditions. 

WARNING: Faulty installation may have serious consequences. 

Installation and all necessary regular maintenance operations must be performed by an 

authorized installer in full accordance with the specifications set out in the legislation 

applicable in each country and this instruction book. 

1.1.

 

General characteristics 

 

Unit 

Sara-Lorea 

Abodi-Andrea 

Nominal Heat Output (N.H.O.) to atmosphere 

kW 

20 

19 

Efficiency at N.H.O. 

80 

76 

CO emission at 13% O2 at N.H.O. 

0.09 

0.39 

Gas mass flow at N.H.O. 

g/s  

15.3 

19 

Gas temperature downstream of flue socket at N.H.O. 

ºC  

297 

400 

Optimum flue draught 

Pa  

12 

12 

Wood consumption (beech) at N.H.O.  

Kg/h  

5.8 

6.4 

Dimensions of the firebox 
    Width 

mm  

700 

700 

    Depth 

mm  

435 

435 

    Useful height 

mm  

500 

500 

Dimensions of the logs 

cm  

30 

30 

Volume heated (45w/m³) at N.H.O. 

m³  

422 

422 

Log load frequency 

Capacity of the ashpit 

3.2 

3.2 

Weight 

kg 

160 

275 

Flue socket diameter 

mm  

250 

250 

Voltage (AC) 

230 

230 

Frequency 

Hz 

50 

50 

 

Note: The values indicated in the above table are based on tests performed in accordance 

with UNE-EN 13229,  with logs with no more than 18% humidity and pressure  conditions as 
indicated in each case. 

 

 

 

Summary of Contents for Sara

Page 1: ...Sara Lorea Abodi Andrea Instruction Book...

Page 2: ...installation 6 2 2 1 Ventilation of the room 6 2 2 2 Location of the appliance in the room 7 2 3 Installation of the appliance 7 2 3 1 Floor 7 2 3 2 Safety distances 7 2 3 3 Checks before lighting for...

Page 3: ...2 1 4 1 2 Inside the appliance 16 4 1 3 Flue socket 16 4 1 4 Firebox glass 16 4 2 Maintenance of the chimney flue 16 4 3 Important advice 16 TROUBLESHOOTING 17 5 BASIC BREAKDOWNS 18 6 DECLARATION OF...

Page 4: ...the legislation applicable in each country and this instruction book 1 1 General characteristics Unit Sara Lorea Abodi Andrea Nominal Heat Output N H O to atmosphere kW 20 19 Efficiency at N H O 80 76...

Page 5: ...the fuel fuel loads fuel load frequencies flue draught and system of installation indicated in this Instruction Book Failure to respect these conditions may lead to problems with the appliance deteri...

Page 6: ...PRESENTATION OF THE APPLIANCE 5 1 Figure No 2 Dimensions of the Abodi Andrea appliance in mm...

Page 7: ...s absolutely crucial to ensure the suitable renewal of the air in the room in which the appliance is fitted The room must always have at least two permanent grilles or openings to the exterior in orde...

Page 8: ...vent breakage deformation etc as a result of overheating if the non combustible material is not designed to withstand high temperatures 2 3 3 Checks before lighting for the first time Make sure that t...

Page 9: ...replacement can be accessed at any time e g counterweight system hydraulic components heating circuit safety components 2 3 6 Connection to the flue The appliance must be connected to the chimney flue...

Page 10: ...rect updraught The diameter of the pipe must be the same as the diameter of the flue socket on the appliance over its entire length in order to ensure correct operation The flue must prevent the entry...

Page 11: ...wn must clear the highest point of any neighbouring building or obstacle located within a 10m radius of the chimney outlet by more than 1m Figure No 7 Distances between the chimney crown and objects w...

Page 12: ...um diameter of 150mm Finely chopped wood produces greater heat output but also burns more quickly Optimum fuels Beech Other fuels Oak chestnut ash maple birch elm etc Pine and eucalyptus logs are low...

Page 13: ...components Figure No 10 Operating components on the appliance A Firebox door handle B Primary air intake o B1 open move right o B2 open move left C Secondary air intake o C1 open move towards the symb...

Page 14: ...when the appliance has been lit three or four times and has adapted to its flue If it does not disappear then check the flue draught length and diameter of the flue flue insulation airtightness and t...

Page 15: ...the parts which make up the appliance Do not be alarmed by noises of this kind In order to obtain maximum output open all the air intakes to the firebox and in order to obtain minimum output tend tow...

Page 16: ...d the appliance inside the shell This air can be piped to other rooms IMPORTANT This appliance is not covered by our warranty unless directly connected to the mains electricity supply in accordance wi...

Page 17: ...are not to apply the glass cleaner directly onto the glass as it could come into contact with the door seal cord and damage it Also make sure that the cleaning liquid does not enter the moving part of...

Page 18: ...hips carpentry scraps plywood pallets etc Cold flue Heat up the flue by burning a piece of paper in the firebox Smoke during burning The room is at low pressure In rooms with Controlled Mechanical Ven...

Page 19: ...BASIC BREAKDOWNS 18 6 BASIC BREAKDOWNS 6 NO TRADUCIR EL TEXTO DE ESTA IMAGEN...

Page 20: ...0850 500000000850 500000000850 10 Registro entrada aire secundario izquierdo 500000000123 500000000123 500000000123 500000000123 11 Registro entrada aire secundario derecho 500000000122 500000000122 5...

Page 21: ...DECLARATION OF PERFORMANCE 20 7 DECLARATION OF PERFORMANCE 7...

Page 22: ...DECLARATION OF PERFORMANCE 21 7...

Page 23: ...DECLARATION OF PERFORMANCE 22 7...

Page 24: ...DECLARATION OF PERFORMANCE 23 7...

Page 25: ...CE MARK 24 8 CE MARK 8...

Page 26: ......

Page 27: ...LACUNZA KALOR GROUP S A L Pol Ind Ibarrea s n 31800 Alsasua Navarra Spain Tel 00 34 948 56 35 11 Fax 00 34 948 56 35 05 e mail comercial lacunza net Website www lacunza net EDITION 0...

Reviews: