INSTRUCTIONS OF USE
20
3.
Figure No.1 -
Dismantling the Silver Plus
deflector
Fitting the part on the flue socket
A circular part is supplied inside the
appliance. This part must be fitted in
position inside the flue in order to achieve
all the values in the UNE-EN 13229,
standard. Because this part causes a lot of
the gases produced by combustion to be
retained, it requires optimum flue and fuel
conditions. Users may, therefore, prefer
not to fit it if such conditions cannot be
ensured.
3.9.
Electrical system
Forced convetion. Fans
Titanium models have 2 fans for the
forced convection of the hot air generated
around the appliance inside the shell. This
air can be piped to other rooms.
IMPORTANT:
This appliance is not
covered by our warranty unless directly
connected to the mains electricity supply in
accordance with the conditions described
in the relevant section in 1.1.
Potentiometer operation:
By means of its rotating lever, the
potentiometer controls the flow of hot-air
output from the appliance in two ways:
•
Automatic mode:
The fan automatically starts working at
the set speed via the thermostat. When a
fire has been lit in the firebox and the
thermostat reaches a temperature of
approximately 50ºC, the fan starts working
at the power set on the potentiometer
(rotating wheel) and stops automatically
when the temperature drops beneath
50ºC.
•
Manual mode:
The fan works at the speed set using the
rotating wheel independently of the
thermostat, i.e. the fan can be started up
before the thermostat reaches 50ºC.
Figure No.2 -
Titanium potentiometer display
Summary of Contents for Titanium Plus
Page 1: ...Titanium Plus Instruction Book...
Page 26: ...BASIC BREAKDOWNS 25 6 BASIC BREAKDOWNS...
Page 27: ...BASIC BREAKDOWNS 26 6...
Page 28: ...BASIC BREAKDOWNS 27 6...
Page 29: ...DECLARATION OF PERFORMANCE 28 7 DECLARATION OF PERFORMANCE...
Page 30: ...DECLARATION OF PERFORMANCE 29 7...
Page 31: ...CE MARK 30 8 CE MARK...