Technical parameters:

 

Type of boiler

 

 

LADAN

 

18

 

25

 

40

 

60 

80 

Boiler output

 

  kW

 

18

 

25

 

40

 

 

60 

 

80 

Feed hopper capacity

 

  dm3

 

75

 

113

 

180

 

250 

360 

Door dimension  /h-w/

 

 mm

 

270x450

 

270x450

 

270x450

 

370x570, 

270x570 

370x570, 

270x570 

Prescribed  chimney draught

 

  Pa

 

10

 

23

 

23

 

28 

32 

Test overpreassure

 

  bar

 

4

 

4

 

4

 

Max. working overpressure

 

  bar

 

2

 

2

 

2

 

Boiler weight

 

  kg

 

360

 

430

 

465

 

620 

735 

Diameter of flue connection

 

 mm

 

160

 

160

 

178

 

178 

178 

Boiler height

 

 mm

 

1280

 

1280

 

1490

 

1490 

1490 

Boiler width

 

 mm

 

595

 

595

 

595

 

715 

715 

Boiler depth

 

 mm

 

855

 

1055

 

1055

 

1380 

1626 

Shielding of electric parts

 

  IP

 

21

 

21

 

21

 

21 

21 

Electrical input

 

  W

 

70

 

70

 

70

 

140 

140 

Hydraulic loss of boiler at 10k

 

 mbar

 

0,21

 

0,31

 

0,54

 

0,84 

1,12 

CO emission class

 

 

4

 

4

 

4

 

Boiler efficiency

 

  %

 

90 

Temp. of flue gas in  

nominal output

 

  °C

 

148

 

146

 

144

 

162 

168 

Flow of flue gas

 

 kg/s

 

0,018

 

0,02

 

0,035

 

0,054 

0,072 

Maximum noise level

 

  dB

 

57

 

57

 

57

 

57 

57 

Specified fuel

 

 wood

 

 Water content max. 

 

20%  

Average fuel consumption

 

  kg/h

 

5,5

 

       7,6

 

         9,5

 

11,8 

14,6 

Recommended  fuel size

 

  mm

 

150

 

      150                

 

         150

 

150 

150 

Max. length of logs

 

 mm

 

350

 

       550

 

         550

 

800 

1000 

Water volume in boiler

 

  l

 

55

 

       75

 

         93

 

113 

132 

Voltage

 

  V/Hz

 

230/50

 

     230/50

 

     230/50

 

230/50 

230/50 

Range of temperature 

of heating

 

  °C

 

60 - 90

 

   60 - 90

 

    60 - 90

 

60-90 

60-90 

Min. water temperature in service

 

  °C

 

60

 

       60

 

         60

 

60 

60 

Operation temperature of water 

 

  °C

 

80 - 90

 

      80 - 90

 

       80 - 90

 

80-90 

80-90 

Safety valve Danfoss BVTS 

 

temperature of inlet water 

 

pressure of inlet water 

 

opening temperature

 

      

    °C 

   Bar   

    °C

 

                                              

        Max. 15          

               2 

              95

 

 

 
 

Summary of Contents for 18

Page 1: ...1 Ladan Wood gasification boiler Instruction for use installation and assembly of boiler ...

Page 2: ...steel plates It includes a feed hopper with a heatproof shaped piece that has an oblong opening nozzle for transit of flue gas Under the nozzle there is a combustion space formed with the ceramic shaped pieces In the rear part of the boiler there are vertical flue tubes which in the upper part go to the collecting channel with a make fire flap Rear part of the collecting channel is fitted with an ...

Page 3: ...ydraulic loss of boiler at 10k mbar 0 21 0 31 0 54 0 84 1 12 CO emission class 4 4 4 4 4 Boiler efficiency 90 Temp of flue gas in nominal output C 148 146 144 162 168 Flow of flue gas kg s 0 018 0 02 0 035 0 054 0 072 Maximum noise level dB 57 57 57 57 57 Specified fuel wood Water content max 20 Average fuel consumption kg h 5 5 7 6 9 5 11 8 14 6 Recommended fuel size mm 150 150 150 150 150 Max le...

Page 4: ...n of Boiler against overheating ATTENTION According to the EN 303 5 standard the Safety cooling circuit against the boiler overheating must not be used for other purposes than to protect boiler against overheating ...

Page 5: ...er overheating and opening of Danfoss BVTS valve there must be secured the permanent drain of heated water from the boiler cooling circuit into spillway Valve at the cold water inlet into the boiler cooling circuit must be permanently open and the boiler cooling circuit must be connected to the functioning distribution of cold water e g cold tap water network of temperature 10 15 C and operating o...

Page 6: ...6 Dimension scheme Boiler sketch ...

Page 7: ...7 ...

Page 8: ...the refilling between the chimney flap and the flange It would make impossible to close flap correctly Cleaning the boiler When using dry wood and optimum fuel gasification the combustion chamber and heat exchanger get sooted minimally However when using wet wood the walls of combustion chamber can be covered with a layer of tar and the boiler does not have an adequate efficiency We remove the tar...

Page 9: ...of the heating season Especially to check the correct function of the safety valve temperature sensor emergancy thermostat and regulation Door tightness The door is attached to the boiler in three points Two hinges and one door handle In case of door leakage it is possible to screw in the door handle but also draw close the hinges Chimney shutter tightness At cleaning of the heat exchanger it is n...

Page 10: ...back from the closed position Smoke escape over the closed door set up the door check the tightness of the door Change the sealing cord of the door Flue shutter does not open Flue shutter is sticked with tar Increase the boiler temperature Use the dry wood Open flue shutter manually After opening the upper door and chimney shutter the boiler room is full of smoke Low flue draught The flue diameter...

Page 11: ... Upper back cover 5 Conduit of primary air 18 Make a fire flap 6 Fan shutter 19 Cover of heat exchanger 7 Fan 20 Flue branch 8 Fireproof nozzle 21 Heat exchanger tubes 9 Covering of secondary air 22 Fireproof concrete 10 Door handle 23 Secondary air 11 Fireclay shaped bricks 24 Combustion chamber 12 Lower door 25 Direction of flue gas 13 Upper front cover 26 Return water socket 27 Filler hole ...

Page 12: ... of thermal sensor and emergency thermostat 1 Upper metal sheet of the boiler 2 Socket of outlet water 2 3 Temperature sensor 4 Emergency thermostat in case the temperature is higher than 110 C the fan turns off ...

Page 13: ...13 Scheme of loading chamber Length of chamber is 590 1000 mm Loading chamber ...

Page 14: ...up valve so that in case of valve untightness the pressure might increase Max overpressure is 0 2 MPa Boiler room must have a good ventilation Assembly of boiler can be done by specialists in compliance with the valid local standards Minimum return water temperature at the inlet to the boiler is 60 C It is recommended the boiler is fitted together with the accumulation tank which must correspond t...

Page 15: ...nce with standards valid in the country of installation Safety instructions On the boiler and to his safety distance it is prohibited to put any combustible item and materials Before you start to work with some changes related the boiler enviroments manipulation with combustible materials etc it is necessary to shutdown the boiler and wait till the boiler burns out The boiler operation must be acc...

Page 16: ... specialized company Warranty is valid only if body of the boiler was connected into the system together with four way valve duomix or other mixing valve Producer is not responsible for incorrect boiler operation due to incorrect boiler connection into the system Guarantee Guarantee does not include the consumable material like door seal heat exchanger seal fan seal fireproof nozzle fireproof bric...

Reviews: