5.6
Mounting profile bar
Mounting profile bar with special screws
Profile bars can be used for standing or hanging trough mounting.
If the profile bar for standing trough mounting is present, the countersink in the mounting holes
for the special screws must be on the groove side.
If the profile bar for hanging trough mounting is present, the countersink in the mounting holes
for the special screws must be on the groove side.
Mounting requirements:
The electric transporter is properly mounted.
The profile bar is available in the required length.
The mounting holes in the profile bar with countersink are present (for the hole pattern of the
fastening holes, see chapter 5.2 "Preparation for mounting" on page 20).
Required mounting material:
Four special screws article number 2299.69.20.02.06 (M6x20)
FIBRO GMBH recommends that all screws be provided with medium-strength thread lock.
1. Position profile bar over the threaded holes of the electric transporter.
2. Insert special screws and tighten crosswise.
Fig. 5-15 Mounting profile bars with special screws
The profile bar is mounted.