5.7
Mounting trough on profile bar
Trough mounting with sliding blocks
Mounting requirements:
The electric transporter is properly mounted.
The profile bar is properly mounted.
The mounting holes in the trough are present and provided with a countersink (for holes and
countersink, see chapter 5.2 "Preparation for mounting" on page 20).
The trough slope in the transport direction must not exceed the value of 8°. A rising trough
can reduce the conveying speed by up to 50%.
Required mounting material:
Trough mounting with sliding blocks
mounting kit article number 2299.69.10.20
(See chapter 5.3 "Mounting material" on page 22).
FIBRO GMBH recommends that all screws be provided with medium-strength thread lock.
1. On the underside of the trough, place the washers on the holes. The washers are self-ad-
hesive and adhere to the trough.
2. Insert the sliding blocks into the grooves of the profile bar and pre-position them.
3. Position the trough over the sliding blocks.
4. Insert countersunk screws and tighten crosswise.
Fig. 5-17 Trough mounting with sliding blocks
The trough is mounted.