Changing the lung
1
.
Detach the chest skin.
2.
Detach the tubing from the elbow valve located under the
chest compression plate as shown in figure 35.
3.
Pull the lung off the compression plate as shown in figure 36.
4.
Attach the new lung.
5.
Reattach the chest skin.
Changing the Stomach
1
.
Detach the chest skin.
2.
Take away the stomach bladder by lifting the simulated stomach
bladder from the torso. Undo the stomach bladder from the
“feet” of the stomach pouch and detach the tubing from stomach
valve as shown in figure 37.
3.
Attach the new stomach bladder.
4.
Reattach the chest skin.
Changing manikin batteries
When replacing worn out batteries, replace them with
eight D-cell alkaline batteries.
To replace batteries:
1
.
Detach chest skin.
2
. Open the battery cover.
3.
Remove and discard old batteries.
4.
Replace new batteries as indicated on battery cover.
5
. Align battery cover with grooves in battery compartment.
6
. Reattach chest skin.
Connecting PC
1
.
Locate the USB connector cable extending from the right side
of the torso.
2.
Plug in USB cable to this connector.
3.
Turn on the manikin
4.
Start the manikin software program on the computer
5.
Establish connection between the manikin and the PC program
by clicking on the “Locate manikin” tab on the “Session Setup”
main screen.