Standard Rotary Pursuit Model 30010A

The Standard Rotary Pursuit interfaces to the 54035A via the pair of binding posts marked “EXT. ON-TARGET 

TIMER”. The red binding post should be connected to the RUN/CNT input on the 54035A and the black binding 

post should be connected to any of the GND inputs.  When connected, the 54035A will show the time on target 

over the length of a trial.  Since the 54035A also counts the switch closure, it will also show total number of times 

on target.  Note that there will be a slight variance between the 54035A and the built-in 30010A timer due to the 

different resolutions of the timers. The 54035A can be set to either single or multiple timer mode for this test.

Steadiness Testers, Groove and Hole Types Models 32010, 32011

Both types of steadiness testers can connect to the 54035A via the RUN/CNT input.  Each tester has a binding 

post on the apparatus.  This binding post should be connected to any GND input on the 54035A.  The stylus for 

the device should be connected to the RUN/CNT input on the 54035A.  The 54035A will show both the number 

of errors and the total time for the errors.  The time value will help the tester know if a subject intentionally 

produces a continuous error in order to reduce the total number of counts.  The 54035A can be set to either 

single or multiple timer mode for these tests.

Tapping Board Model 32012

The 54035A connects to the 32012 via the RUN/CNT input. The binding post on the board connects to any GND 

input on the 54035A.  The stylus for the tapping board connects to the RUN/CNT input. The 54035A will show 

the number of counts or taps along with the contact time for each tap. The time reading for this experiment 

can be disregarded. The 54035A can be set to either single or multiple timer mode for this test.

Mirror Tracer/Two Arm Coordination tests Models 58024A, 32532

The 54035A can be used with both of these tests to time and count responses. The 58024A comes with its own 

counter, but the 54035A can be substituted if desired. To set up, connect the black binding post on the device 

to any GND input on the 54035A. Connect the red binding post to the RUN/CNT input. The 54035A will show 

total number of errors and the total time off target. The 54035A can be set to either single or multiple timer 

mode for these tests.

Visual Choice Reaction Timer Model 63035

The 54035A can be used with the 63035 to record response time. To set up, connect the black binding post on 

the side of the 63035 to any GND input on the rear of 54035A. Connect the red binding post to the RUN/CNT 

input on the 54035A.  The 54035A will show the total time between the stimulus and response. The 54035A 

will also show counts, but they can be ignored. The 54035A can be set to either single or multiple timer mode 

for this test.

Linear Movement Apparatus Model 31202

The 54035A can be used with the Linear Movement Apparatus to show total movement time. To setup, program 

the timer for single timer mode with one split time (this is the default mode when the timer is turned on). 

Connect both black terminals to any GND input on the 54035A. Connect the green terminal to the START input 

and the red terminal to the STOP1 input.

Summary of Contents for 54035A

Page 1: ...t com Model 54035A Multifunction Timer Counter User s Manual 3700 Sagamore Parkway North Lafayette IN 47904 USA Tel 765 423 1505 800 428 7545 Fax 765 423 4111 info lafayetteinstrument com www lafayett...

Page 2: ...ion Timer Counter Model 54035A is designed to time and count events with high accuracy and high resolution It features millisecond timing up to 1000 seconds and counting up to 1000 counts It can take...

Page 3: ...mode button on the front panel or via instructions on the serial communication port seeCommunications directions pg 9 for details In order to enter the mode menu the timer must be reset Single Mode T...

Page 4: ...ation To prevent accidental loss of data the timer must be reset before the mode menu can be entered If single timer operation is selected the timer will give a prompt for the desired number of split...

Page 5: ...external input is the only way to activate run1 count1 3 Stop2 Run2 In single timer mode this input is for stop2 in multiple timer mode it is for run count2 This external input is the only way to act...

Page 6: ...ries is provided on the bottom of the 54035A Using a screwdriver or coin turn each of the thumbscrews and remove the battery cover plate The batteries are provided with two ribbon loops to aid in remo...

Page 7: ...sends and receives only ASCII characters Each control is activated by sending a single ASCII character the timer is case sensitive ASCII Function S Start 1 Stop1 2 Stop2 3 Stop3 4 Stop4 C Begin run c...

Page 8: ...1 Selecting the comm port in use by the mouse will result in an error and or disabling of the mouse If the mouse is disabled the computer will have to be restarted to restore function Timing function...

Page 9: ...g results start and stop the timer from the front or back panel on the 54035A and use the computer to upload the time data Results File Format All time and count data is stored in an ASCII format Any...

Page 10: ...D input on the timer The54035Awilldisplaythetimeontargetonthemaintimer timeofftargetontimer1andtherevolutioncount on timer 2 press scroll in multiple timer mode to view timer 2 data If the rotary purs...

Page 11: ...binding posts on the Stability Platform to an input and ground on the 54035A 2 Connect the center binding post to the RUN CNT input 3 Connect the right binding post to RUN1 input 4 Connect the left bi...

Page 12: ...nding posts on the Stability Platform to an input and ground on the 54035A 2 Connect the center binding post to the RUN CNT input 3 Connect the right binding post to RUN1 input 4 Connect the left bind...

Page 13: ...rom the maze to the START input on the Multifunction Timer Counter 3 Connect the stop jack from the maze to STOP3 on the timer 4 Connect the error jack on the maze to RUN1 on the timer 5 Connect the s...

Page 14: ...t of each switch to the one of the four GND inputs on the rear of the 54035A To start an event a remote pushbutton can be connected to the START input on the rear of the 54035A or a trial can begin by...

Page 15: ...ing post on the board connects to any GND input on the 54035A The stylus for the tapping board connects to the RUN CNT input The 54035A will show the number of counts or taps along with the contact ti...

Page 16: ...ranty repairs Damaged Goods Damaged instrumentation should not be returned to Lafayette Instrument prior to a thorough inspection If a shipment arrives damaged note damage on delivery bill and have th...

Reviews: