10. 

Change Subject: 

 This button allows the user to perform multiple tests in the same storage file. The test 

data for each new subject is kept in a separate table inside the same storage file. The subject entry is used 

to identify each data table. This feature is useful for running multiple subjects on the same test.

11. 

Save Data: 

 This button stores the time and count data on the screen into the file designated by the user. 

The user must designate a file and subject before data can be stored.

12. 

Auto Store Data:  

This selection will automatically store the present time and count data anytime the 

following buttons are pressed: Stop1, Stop2, Stop3, Stop4, Reset, and Update data. To activate this function, 

click the check box under the “Save Data” button. When the box is checked, the auto store function is in 

effect. Upon checking the box, the software will prompt the user to designate a storage file and subject 

name.

Notes

• 

If  the timer is set to Multiple timer mode, all four stops will record on split time 1.

• 

If the computer is used to start and stop events, there will be a slight delay ( a few milliseconds) between 

the pressing of the button, and the execution of the event on the LCD screen of the 54035A. This delay may 

or may not be noticeable to the user. It is due to the serial communication timing and can not be improved. 

For the most accurate timing results, start and stop the timer from the front or back panel on the 54035A 

and use the computer to upload the time data.

Results File Format

All time and count data is stored in an ASCII format. Any program capable of reading this format can be used 

to view the data (Excel, Notepad, Word etc.). Please note that if the 54035A software has opened a file, it may 

not be possible to view the file until the 54035A software is exited. Each set of data in the file has a header that 

includes the subject name and the time and date the file was created. Each time a “Save data” command or auto 

store command is given, a line is entered in the results table showing the time and count data present on the 

54035A at the time of the command. An event column shows which command in the software triggered each 

line of data to be stored. A separate table is given for each different subject inside the storage file. 

Applications

Directions in this section (next seven pages) detail setup procedures for interfacing the Multifunction Timer/

Counter to specific Lafayette Instrument equipment. If the equipment being used does not appear on this list, 

contact Lafayette Instrument for application instructions.

Setting the Timer to Multiple time mode

 

Many applications in this section require the timer to be set up in “multiple” timer mode. To do this setup, 

simply press the mode button and select “2-multiple” by pressing “2”. Make sure that the timer is stopped and 

reset before attempting to enter the mode menu. The mode menu will then prompt to set the switch types. 

Unless the application calls for normally closed switches, exit this portion of the menu by pressing “3” for “end”.

Summary of Contents for 54035A

Page 1: ...t com Model 54035A Multifunction Timer Counter User s Manual 3700 Sagamore Parkway North Lafayette IN 47904 USA Tel 765 423 1505 800 428 7545 Fax 765 423 4111 info lafayetteinstrument com www lafayett...

Page 2: ...ion Timer Counter Model 54035A is designed to time and count events with high accuracy and high resolution It features millisecond timing up to 1000 seconds and counting up to 1000 counts It can take...

Page 3: ...mode button on the front panel or via instructions on the serial communication port seeCommunications directions pg 9 for details In order to enter the mode menu the timer must be reset Single Mode T...

Page 4: ...ation To prevent accidental loss of data the timer must be reset before the mode menu can be entered If single timer operation is selected the timer will give a prompt for the desired number of split...

Page 5: ...external input is the only way to activate run1 count1 3 Stop2 Run2 In single timer mode this input is for stop2 in multiple timer mode it is for run count2 This external input is the only way to act...

Page 6: ...ries is provided on the bottom of the 54035A Using a screwdriver or coin turn each of the thumbscrews and remove the battery cover plate The batteries are provided with two ribbon loops to aid in remo...

Page 7: ...sends and receives only ASCII characters Each control is activated by sending a single ASCII character the timer is case sensitive ASCII Function S Start 1 Stop1 2 Stop2 3 Stop3 4 Stop4 C Begin run c...

Page 8: ...1 Selecting the comm port in use by the mouse will result in an error and or disabling of the mouse If the mouse is disabled the computer will have to be restarted to restore function Timing function...

Page 9: ...g results start and stop the timer from the front or back panel on the 54035A and use the computer to upload the time data Results File Format All time and count data is stored in an ASCII format Any...

Page 10: ...D input on the timer The54035Awilldisplaythetimeontargetonthemaintimer timeofftargetontimer1andtherevolutioncount on timer 2 press scroll in multiple timer mode to view timer 2 data If the rotary purs...

Page 11: ...binding posts on the Stability Platform to an input and ground on the 54035A 2 Connect the center binding post to the RUN CNT input 3 Connect the right binding post to RUN1 input 4 Connect the left bi...

Page 12: ...nding posts on the Stability Platform to an input and ground on the 54035A 2 Connect the center binding post to the RUN CNT input 3 Connect the right binding post to RUN1 input 4 Connect the left bind...

Page 13: ...rom the maze to the START input on the Multifunction Timer Counter 3 Connect the stop jack from the maze to STOP3 on the timer 4 Connect the error jack on the maze to RUN1 on the timer 5 Connect the s...

Page 14: ...t of each switch to the one of the four GND inputs on the rear of the 54035A To start an event a remote pushbutton can be connected to the START input on the rear of the 54035A or a trial can begin by...

Page 15: ...ing post on the board connects to any GND input on the 54035A The stylus for the tapping board connects to the RUN CNT input The 54035A will show the number of counts or taps along with the contact ti...

Page 16: ...ranty repairs Damaged Goods Damaged instrumentation should not be returned to Lafayette Instrument prior to a thorough inspection If a shipment arrives damaged note damage on delivery bill and have th...