SAFETY & OPERATIONAL PRECAUTIONS

See Additional Safety Precautions included with the Electrical Control Box Installation Information
Always consider electrical shock hazard when working with and handling electrical equipment. If
uncertain, consult an Electrician. Electrical wiring should only be done by a qualified Electrician, per
Local and State Electrical Codes

.

Manufacturer assumes no liability for the use or misuse of this unit.
Wear proper respiratory protection, protective clothing, gloves and eye-wear when working with chemicals.
Always direct the discharge away from electrical devices.
Carefully follow chemical manufacturer's safe handling instructions and recommended precautions/practices
especially when using flammable chemicals.
For proper performance do NOT modify electrical control box.
Disconnect electrical power to the control box prior to opening it.
Remove any packing material from inside the control box before operating.

SPECIAL CAUTION: This fogger atomizes chemical into the air.  Ensure that the chemical is safe to be
around or the area to be fogged has been evacuated of all people and/or animals before starting fogging.
Upon completion of fogging, ensure that sufficient time has elapsed for all the fog to have dissipated
before returning to the area without proper respiratory protection.

TO INSTALL (REFER TO DIAGRAM ON NEXT PAGE)

1.  Unpack and connect the 4-way fogger head to the nipples as shown in the drawing
2.  (4) pick up tube ends are sticking out of the tank lid, push them over the 4 blue metering tip holders. Place the

same tube on the 2 foggers with the ball valves. This allows the unit to be used as a 2-way.

3.  Test using water to familiarize yourself with the fogger before running chemicals through it.

SETTING THE TIMER

1.  Make sure the system is not plugged in to a power source. Open the control box cover. The box contains one

timer with both "Delay & Run" adjustment knobs. 

Delay:

 This mode allows you to set the length of time you want the unit to to be inactive for before fogging

begins. Set the timer by turning the knob to the amount of delay time that you require. (0-6 Hours) 

Run:

 This mode allows you to set the length of time you want the fogger to run for after the delay period has

expired. Set the timer by turning the knob to the amount of run time that you require. (0-60 Minutes)

2.  Close and lock the control box cover.
3.  Plug the power cord into a 120 VAC power outlet. GFI recommended.

SWITCH SETTINGS

 (There are two lighted rocker switches on the front of the control box.)

1.  The switch on the left is labeled "On/Off/Auto Ready". With the switch in the "Off" position there is no power to

the unit and there are no lights illuminated.

 Caution: If the switch is set to the "On" position, the green light

is illuminated and the unit will automatically start fogging

This is useful during setup and testing with

water. Otherwise this setting should be used with care.

2.  When the timers have been adjusted to required settings, the switch should be set to "Auto Ready". The red light

illuminates and this provides power to the second switch on the right hand side of the control box.

3.  The switch on the right is labeled "Auto Initiate". When you are ready to initiate the "Delay/Run" sequence, press

the top of the switch to "Auto Initiate". The green light on this switch is now illuminated. The fogger is now in
Delay mode and will perform according to preset times.

Note:

 If power is interrupted after timers have been set, the system stops all timer operations and needs to be reset.

SETTING AND ADJUSTING FOG DENSITY

1.  Use a separate container of water to set and adjust the fog density. Place the  pick-up tubes into the water.
2.  Place the fogger in the center of the area to be fogged.
3.  Loosen the "L"bolts on the slide brackets, raise the 4-way fogger assembly to preferred height, and tighten
4.  Set the Delay Timer knob for a minimal amount of time (enough time for you to move away from the fogger) and

set the Run Timer knob for about 1 minute (enough time for you to observe the fog density.)

5.  Connect your 1/2" minimum air line to the fogger. Turn on your air and electricity supply. 
6.  Set the rocker switches on the control box as described above.
7.  Move away from the fogger and observe the fogger's performance. 

The fog should be consistent and uniform.

If it is sputtering and inconsistent you may need to partially close your airline ball valve to fine tune the
air volume/pressure. Best results are achieved at around 60 PSI.

8.  You will have to experiment with the amount of time and solution required to achieve the desired result.
9.  If fog is more dense than the application requires, optional metering tips are available for restricting the solution

volume to produce a lighter fog.

10.  Once you are familiar with coverage, operation and air flow adjustments you are ready to fog.

TO OPERATE

1.  Fill the tank with the desired amount of ready to use solution and insert the suction tubes in the tank.
2.  With the fogger in the center of the area to be fogged and adjust fogger assembly to preferred height.
3.  Set the timers to the desired Delay and Run times (see above).
4.  Turn on your air and electricity supplies. Set the rocker switches as described above.
5.  Turn air supply off when finished and ensure that the area is safe before returning

PORTABLE 305 4-WAY FOGGER

PRODUCE MEDIUM FOG PARTICLES AND

PROJECT A LIGHTER, "DAMP" MIST UP TO 25

FEET.

COMPRESSED AIR FLOW (CFM)

PLUMES

60 PSI

80 PSI

4-Way

22.5

29.5

CHEMICAL SOLUTION DRAW RATE (FL-OZ/MIN)

DISTANCE

60 PSI

80 PSI

80" Above Chemical

31.6

39.5

60" Above Chemical

37.4

44.2

950721-TD • Portable Timed / Delay 20 Gallon 305 4-Way Fogger

- Page 2 -

Summary of Contents for 950700

Page 1: ...PDM WEIGHT DIMENSIONS Single Package Shipping Weight 41 lbs Shipping Dimensions 43 x 26 x 16 www laffertyequipment com 501 851 2820 OVERVIEW The Portable 5 Gallon 633 4 Way Fogger is a chemical atomiz...

Page 2: ...y produce more volume than needed If fog is too dense optional metering tips are available for restricting the solution volume to produce a lighter fog 10 Observe the coverage you may have to move the...

Page 3: ...950700 Portable 5 Gallon 633 4 Way Fogger Page 3...

Page 4: ...5 Drawing too much solution Order and install optional metering tip or needle valve needle valve 4 8 Way only 6 Pin hole or cut in suction tube Replace suction tube 7 Chemical strainer clogged up Cle...

Page 5: ...1 4 EPDM WEIGHT DIMENSIONS Single Package Shipping Weight 41 lbs Shipping Dimensions 16 x 26 x 43 www laffertyequipment com 501 851 2820 OVERVIEW The Portable 5 Gallon 305 4 Way Fogger is a chemical a...

Page 6: ...re volume than needed If fog is too dense optional metering tips are available for restricting the solution volume to produce a lighter fog 10 Observe the coverage you may have to move the fogger a ti...

Page 7: ...950701 Portable 5 Gallon 305 4 Way Fogger Page 3...

Page 8: ...5 Drawing too much solution Order and install optional metering tip or needle valve needle valve 4 8 Way only 6 Pin hole or cut in suction tube Replace suction tube 7 Chemical strainer clogged up Cle...

Page 9: ...High Volume Mixing Station 9 9 GPM WEIGHT DIMENSIONS Single Package Shipping Weight 66 lbs Shipping Dimensions 48 x 26 x 24 www laffertyequipment com 501 851 2820 OVERVIEW The Portable 20 Gallon 305 4...

Page 10: ...foggers may produce more volume than needed If fog is too dense optional metering tips are available for restricting the solution volume to produce a lighter fog 10 Observe the coverage you may have...

Page 11: ...950721 Portable 20 Gallon 305 4 Way Fogger Page 3...

Page 12: ...5 Drawing too much solution Order and install optional metering tip or needle valve needle valve 4 8 Way only 6 Pin hole or cut in suction tube Replace suction tube 7 Chemical strainer clogged up Cle...

Page 13: ...4 lbs Shipping Dimensions 48 x 26 x 24 www laffertyequipment com 501 851 2820 OVERVIEW The Portable Timed Delay 20 Gallon 305 4 Way Fogger is a chemical atomizer that uses compressed air 29 5 CFM 80 P...

Page 14: ...o the On position the green light is illuminated and the unit will automatically start fogging This is useful during setup and testing with water Otherwise this setting should be used with care 2 When...

Page 15: ...950721 TD Portable Timed Delay 20 Gallon 305 4 Way Fogger Page 3...

Page 16: ...l optional metering tip or needle valve 4 8 Way only 6 Timer failed Replace timer 7 May have electrical problems Ensure circuit breaker 5 Amp has not been tripped Have a qualified electrician check el...